1
/
of
1
ELK Biotechnology
SKU:ELK8747
Human HLA-DR(Leukocyte Antigen DR) ELISA Kit
Human HLA-DR(Leukocyte Antigen DR) ELISA Kit
Regular price
$458.00 USD
Regular price
Sale price
$458.00 USD
Unit price
/
per
Shipping calculated at checkout.
Couldn't load pickup availability
Human HLA-DR(Leukocyte Antigen DR) ELISA Kit
Overview
| Product name: | Human HLA-DR(Leukocyte Antigen DR) ELISA Kit |
| Reactivity: | Human |
| Alternative Names: | HALDR; Human leukocyte antigen DR |
| Assay Type: | Sandwich |
| Sensitivity: | 12.7 pg/mL |
| Standard: | 2000 pg/mL |
| Detection Range: | 31.25-2000 pg/mL |
| Sample Type: | serum, plasma, tissue homogenates and other biological fluids |
| Assay Length: | 3.5h |
| Research Area: | Immune molecule |
| Test principle: | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human HLA-DR. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human HLA-DR. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human HLA-DR, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human HLA-DR in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 2000.00 | 2.126 | 2.033 |
| 1000.00 | 1.679 | 1.586 |
| 500.00 | 1.186 | 1.093 |
| 250.00 | 0.805 | 0.712 |
| 125.00 | 0.539 | 0.446 |
| 62.50 | 0.357 | 0.264 |
| 31.25 | 0.219 | 0.126 |
| 0.00 | 0.093 | 0.000 |

Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant HLA-DR and the recovery rates were calculated by comparing the measured value to the expected amount of HLA-DR in samples.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 80-97% | 88% |
| EDTA plasma(n=5) | 83-95% | 89% |
| Heparin plasma(n=5) | 90-105% | 97% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of HLA-DR and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 92-101% | 82-98% | 89-97% | 85-93% |
| EDTA plasma(n=5) | 87-102% | 85-94% | 87-101% | 89-99% |
| Heparin plasma(n=5) | 95-104% | 85-96% | 87-102% | 91-99% |
Share