1
/
of
1
ELK Biotechnology
SKU:ELK8719
Human sVEGFR-1(soluble Vascular Endothelial Growth Factor Receptor 1) ELISA Kit
Human sVEGFR-1(soluble Vascular Endothelial Growth Factor Receptor 1) ELISA Kit
Regular price
$376.00 USD
Regular price
Sale price
$376.00 USD
Unit price
/
per
Shipping calculated at checkout.
Couldn't load pickup availability
Human sVEGFR-1(soluble Vascular Endothelial Growth Factor Receptor 1) ELISA Kit
Overview
| Product name: | Human sVEGFR-1(soluble Vascular Endothelial Growth Factor Receptor 1) ELISA Kit |
| Reactivity: | Human |
| Alternative Names: | Svegfr-1 |
| Assay Type: | Sandwich |
| Sensitivity: | 3 pg/mL |
| Standard: | 500 pg/mL |
| Range: | 7.82-500 pg/mL |
| Sample Type: | serum, plasma, tissue homogenates, saliva, cell lysates, follicular fluid and other biological fluids |
| Assay Length: | 3.5h |
| Research Area: | Signal transduction;Tumor immunity; |
| Test principle: | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human sVEGFR-1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human sVEGFR-1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human sVEGFR-1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human sVEGFR-1 in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 500.00 | 2.054 | 1.952 |
| 250.00 | 1.527 | 1.425 |
| 125.00 | 1.034 | 0.932 |
| 62.50 | 0.835 | 0.733 |
| 31.25 | 0.527 | 0.425 |
| 15.63 | 0.352 | 0.250 |
| 7.82 | 0.267 | 0.165 |
| 0.00 | 0.102 | 0.000 |

Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant sVEGFR-1 and the recovery rates were calculated by comparing the measured value to the expected amount of sVEGFR-1 in samples.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 88-103% | 95% |
| EDTA plasma(n=5) | 95-107% | 101% |
| Heparin plasma(n=5) | 80-95% | 87% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of sVEGFR-1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 95-104% | 82-96% | 92-105% | 83-92% |
| EDTA plasma(n=5) | 78-92% | 83-96% | 95-107% | 87-102% |
| Heparin plasma(n=5) | 82-94% | 85-96% | 78-90% | 91-99% |
Share