Overview
| Product name: | Human DHEA-S(Dehydroepiandrosterone sulfate) ELISA Kit |
| Reactivity: | Human |
| Alternative Names: | Androstenolone sulfate; Prasterone sulfate; Androst-5-en-3β-ol-17-one 3β-sulfate |
| Assay Type: | Competitive Inhibition |
| Sensitivity: | 4.25 ng/mL |
| Standard: | 400 ng/mL |
| Range: | 6.25-400 ng/mL |
| Sample Type: | Serum, plasma and other biological fluids. |
| Assay Length: | 2h |
| Research Area: | Endocrinology;Reproductive science;Hormone metabolism;Rheumatology; |
| Test principle: | This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Human DHEA-S protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human DHEA-S. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human DHEA-S in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 400.00 | 0.212 | — |
| 200.00 | 0.397 | — |
| 100.00 | 0.612 | — |
| 50.00 | 0.833 | — |
| 25.00 | 1.169 | — |
| 12.50 | 1.537 | — |
| 6.25 | 1.762 | — |
| 0.00 | 2.112 | — |

Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant DHEA-S and the recovery rates were calculated by comparing the measured value to the expected amount of DHEA-S in samples.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 88-96% | 92% |
| EDTA plasma(n=5) | 95-107% | 101% |
| Heparin plasma(n=5) | 81-95% | 88% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of DHEA-S and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 85-95% | 79-96% | 85-101% | 79-90% |
| EDTA plasma(n=5) | 86-93% | 93-101% | 86-97% | 90-101% |
| Heparin plasma(n=5) | 85-94% | 83-92% | 89-98% | 85-94% |