1
/
of
1
ELK Biotechnology
SKU:ELK8524
Human 5-HT(5-Hydroxytryptamine) ELISA Kit
Human 5-HT(5-Hydroxytryptamine) ELISA Kit
Regular price
$376.00 USD
Regular price
Sale price
$376.00 USD
Unit price
/
per
Shipping calculated at checkout.
Couldn't load pickup availability
Human 5-HT(5-Hydroxytryptamine) ELISA Kit
Overview
| Product name: | Human 5-HT(5-Hydroxytryptamine) ELISA Kit |
| Reactivity: | Human |
| Alternative Names: | 5HT; Serotonin; N-Methyl-Gamma |
| Assay Type: | Competitive Inhibition |
| Sensitivity: | 3.97 ng/mL |
| Standard: | 900 ng/mL |
| Range: | 14.07-900 ng/mL |
| Sample Type: | serum, plasma, tissue homogenates |
| Assay Length: | 2h |
| Research Area: | Signal transduction;Infection immunity;Neuro science;Gastroenterology; |
| Test principle: | This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Human 5-HT protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human 5-HT. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human 5-HT in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 900.00 | 0.235 | — |
| 450.00 | 0.432 | — |
| 225.00 | 0.655 | — |
| 112.50 | 0.895 | — |
| 56.25 | 1.189 | — |
| 28.13 | 1.579 | — |
| 14.07 | 1.733 | — |
| 0.00 | 2.028 | — |

Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant 5-HT and the recovery rates were calculated by comparing the measured value to the expected amount of 5-HT in samples.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 80-95% | 87% |
| EDTA plasma(n=5) | 78-96% | 87% |
| Heparin plasma(n=5) | 78-92% | 87% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of 5-HT and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 79-93% | 89-97% | 92-105% | 83-92% |
| EDTA plasma(n=5) | 87-96% | 85-98% | 89-102% | 85-98% |
| Heparin plasma(n=5) | 79-93% | 82-96% | 92-105% | 83-92% |
Share