Human 15-HETE(15-Hydroxyeicosatetraenoic Acid) ELISA Kit
Overview
| Product name: | Human 15-HETE(15-Hydroxyeicosatetraenoic Acid) ELISA Kit |
| Reactivity: | Human |
| Alternative Names: | 15-HETE; 15-Hydroxyeicosatetraenoic Acid) |
| Assay Type: | Competitive Inhibition |
| Sensitivity: | 0.1 ng/mL |
| Standard: | 8 ng/mL |
| Range: | 0.13-8 ng/mL |
| Sample Type: | serum, plasma, cell lysates, cell culture supernates and other biological fluids |
| Assay Length: | 2h |
| Research Area: | Signal transduction;Metabolic pathway;Infection immunity;Hormone metabolism;Dermatology; |
| Test principle: | This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Human 15-HETE protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human 15-HETE. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human 15-HETE in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 8.00 | 0.199 | — |
| 4.00 | 0.433 | — |
| 2.00 | 0.596 | — |
| 1.00 | 0.933 | — |
| 0.50 | 1.156 | — |
| 0.25 | 1.511 | — |
| 0.13 | 1.761 | — |
| 0.00 | 2.211 | — |

Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant 15-HETE and the recovery rates were calculated by comparing the measured value to the expected amount of 15-HETE in samples.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 95-107% | 101% |
| EDTA plasma(n=5) | 82-95% | 88% |
| Heparin plasma(n=5) | 80-94% | 92% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of 15-HETE and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 95-103% | 79-97% | 96-105% | 95-103% |
| EDTA plasma(n=5) | 92-101% | 87-98% | 85-92% | 79-96% |
| Heparin plasma(n=5) | 85-94% | 79-96% | 92-101% | 83-90% |