1
/
of
1
ELK Biotechnology
SKU:ELK8180
Pig Anti-SST(Anti-Somatostatin Antibody) ELISA Kit
Pig Anti-SST(Anti-Somatostatin Antibody) ELISA Kit
Regular price
$588.00 USD
Regular price
Sale price
$588.00 USD
Unit price
/
per
Shipping calculated at checkout.
Couldn't load pickup availability
Pig Anti-SST(Anti-Somatostatin Antibody) ELISA Kit
Overview
| Product name: | Pig Anti-SST(Anti-Somatostatin Antibody) ELISA Kit |
| Reactivity: | Pig |
| Alternative Names: | GHIH; SRIF; SMST; GHRIH; GHRIF; Growth Hormone Releasing Inhibiting Hormone; Somatotropin Release-Inhibiting Factor; Somatostatin-14; Somatostatin-28 |
| Assay Type: | Competitive Inhibition |
| Sensitivity: | 1.24 ng/mL |
| Standard: | 200 ng/mL |
| Range: | 3.13-200 ng/mL |
| Sample Type: | serum, plasma and other biological fluids |
| Assay Length: | 2h, 30min |
| Research Area: | Tumor immunity;Endocrinology;Hormone metabolism; |
| Test principle: | This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Pig Anti-SST protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Pig Anti-SST. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Pig Anti-SST in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 200.00 | 0.191 | — |
| 100.00 | 0.386 | — |
| 50.00 | 0.655 | — |
| 25.00 | 0.878 | — |
| 12.50 | 1.139 | — |
| 6.25 | 1.578 | — |
| 3.13 | 1.796 | — |
| 0.00 | 2.232 | — |

Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant Anti-SST and the recovery rates were calculated by comparing the measured value to the expected amount of Anti-SST in samples.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 95-107% | 101% |
| EDTA plasma(n=5) | 90-105% | 97% |
| Heparin plasma(n=5) | 97-105% | 101% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Anti-SST and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 88-97% | 78-96% | 80-99% | 89-97% |
| EDTA plasma(n=5) | 93-104% | 87-96% | 82-95% | 78-99% |
| Heparin plasma(n=5) | 95-104% | 93-105% | 82-101% | 91-103% |
Share