1
/
of
1
ELK Biotechnology
SKU:ELK7990
Sheep IFNa(Interferon Alpha) ELISA Kit
Sheep IFNa(Interferon Alpha) ELISA Kit
Regular price
$588.00 USD
Regular price
Sale price
$588.00 USD
Unit price
/
per
Shipping calculated at checkout.
Couldn't load pickup availability
Sheep IFNa(Interferon Alpha) ELISA Kit
Overview
| Product name: | Sheep IFNa(Interferon Alpha) ELISA Kit |
| Reactivity: | Sheep |
| Alternative Names: | IFNα1; IFL; LeIF D; IFN; IFN-Alpha; IFNα13; IFN-A; IFNαP22; IFN-Alpha 1b; Interferon Alpha 1b; Interferon, Leukocytic; IFN, Leukocyte; Interferon alpha-D |
| Assay Type: | Sandwich |
| Sensitivity: | 5.5 pg/mL |
| Standard: | 1000 pg/mL |
| Detection Range: | 15.63-1000 pg/mL |
| Sample Type: | Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids. |
| Assay Length: | 3.5h |
| Research Area: | Cytokine;Infection immunity; |
| Test principle: | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Sheep IFNa. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Sheep IFNa. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Sheep IFNa, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Sheep IFNa in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 1000.00 | 2.045 | 1.958 |
| 500.00 | 1.603 | 1.516 |
| 250.00 | 1.240 | 1.153 |
| 125.00 | 0.839 | 0.752 |
| 62.50 | 0.573 | 0.486 |
| 31.25 | 0.318 | 0.231 |
| 15.63 | 0.172 | 0.085 |
| 0.00 | 0.087 | 0.000 |

Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant IFNa and the recovery rates were calculated by comparing the measured value to the expected amount of IFNa in samples.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 82-97% | 89% |
| EDTA plasma(n=5) | 80-95% | 87% |
| Heparin plasma(n=5) | 86-99% | 92% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of IFNa and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 83-98% | 88-97% | 96-105% | 86-92% |
| EDTA plasma(n=5) | 88-95% | 98-107% | 90-99% | 88-97% |
| Heparin plasma(n=5) | 83-95% | 88-102% | 85-97% | 80-92% |
Share