1
/
of
1
ELK Biotechnology
SKU:ELK7427
Pig EDN1(Endothelin 1) ELISA Kit
Pig EDN1(Endothelin 1) ELISA Kit
Regular price
$588.00 USD
Regular price
Sale price
$588.00 USD
Unit price
/
per
Shipping calculated at checkout.
Couldn't load pickup availability
Pig EDN1(Endothelin 1) ELISA Kit
Overview
| Product name: | Pig ET-1(Endothelin1) ELISA Kit |
| Reactivity: | Pig |
| Alternative Names: | ET1; PPET1; Preproendothelin-1; Big endothelin-1; EDN1 |
| Assay Type: | Sandwich |
| Sensitivity: | 4.74 pg/mL |
| Standard: | 1000 pg/mL |
| Range: | 15.63-1000 pg/mL |
| Sample Type: | serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids |
| Assay Length: | 3.5h |
| Research Area: | Endocrinology;Cardiovascular biology; |
| Test principle: | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Pig ET-1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Pig ET-1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Pig ET-1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Pig ET-1 in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 1000.00 | 2.128 | 2.043 |
| 500.00 | 1.609 | 1.524 |
| 250.00 | 1.137 | 1.052 |
| 125.00 | 0.889 | 0.804 |
| 62.50 | 0.649 | 0.564 |
| 31.25 | 0.341 | 0.256 |
| 15.63 | 0.232 | 0.147 |
| 0.00 | 0.085 | 0.000 |

Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant ET-1 and the recovery rates were calculated by comparing the measured value to the expected amount of ET-1 in samples.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 85-97% | 91% |
| EDTA plasma(n=5) | 95-107% | 101% |
| Heparin plasma(n=5) | 82-95% | 88% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ET-1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 85-94% | 87-101% | 86-97% | 88-95% |
| EDTA plasma(n=5) | 88-97% | 90-99% | 85-97% | 79-101% |
| Heparin plasma(n=5) | 78-94% | 97-105% | 88-101% | 82-96% |
Share