Skip to product information
1 of 1

ELK Biotechnology

SKU:ELK5762

Dog ACTH(Adrenocorticotropic Hormone) ELISA Kit

Dog ACTH(Adrenocorticotropic Hormone) ELISA Kit

Regular price $588.00 USD
Regular price Sale price $588.00 USD
Sale Sold out
Shipping calculated at checkout.
Size
Sensitivity
Detection range

Dog ACTH(Adrenocorticotropic Hormone) ELISA Kit

Overview

Product name: Dog ACTH(Adrenocorticotropic Hormone) ELISA Kit
Reactivity: Dog
Alternative Names: Corticotropin; Adrenocorticotropin
Assay Type: Competitive Inhibition
Sensitivity: 4.75 pg/mL
Standard: 1000 pg/mL
Range: 15.63-1000 pg/mL
Sample Type: Serum, plasma and other biological fluids.
Assay Length: 2h
Research Area: Endocrinology;Hormone metabolism;Urology;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Dog ACTH protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Dog ACTH. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Dog ACTH in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (ng/mL) OD Corrected OD
1000.00 0.191
500.00 0.275
250.00 0.451
125.00 0.899
62.50 1.139
31.25 1.537
15.63 1.624
0.00 2.157

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant ACTH and the recovery rates were calculated by comparing the measured value to the expected amount of ACTH in samples.
Matrix Recovery range Average
serum(n=5) 82-98% 90%
EDTA plasma(n=5) 82-94% 88%
Heparin plasma(n=5) 80-97% 96%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ACTH and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 86-93% 91-98% 97-105% 91-99%
EDTA plasma(n=5) 88-102% 86-92% 81-93% 89-104%
Heparin plasma(n=5) 81-94% 81-96% 93-106% 82-95%
View full details