Human ACTN3(Actinin Alpha 3) ELISA Kit
Human ACTN3(Actinin Alpha 3) ELISA Kit
Regular price
$376.00 USD
Regular price
Sale price
$376.00 USD
Unit price
/
per
Shipping calculated at checkout.
Couldn't load pickup availability
Human ACTN3(Actinin Alpha 3) ELISA Kit
Overview
| Product name: | Human ACTN3(Actinin Alpha 3) ELISA Kit |
| Reactivity: | Human |
| Alternative Names: | Alpha-actinin skeletal muscle isoform 3; F-actin cross-linking protein |
| Assay Type: | Sandwich |
| Sensitivity: | 0.62 ng/mL |
| Standard: | 100 ng/mL |
| Range: | 1.57-100 ng/mL |
| Sample Type: | Tissue homogenates, cell lysates and other biological fluids. |
| Assay Length: | 3.5h |
| Research Area: | Metabolic pathway;Developmental science;Bone metabolism; |
| Test principle: | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human ACTN3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human ACTN3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human ACTN3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human ACTN3 in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 100.00 | 2.164 | 2.073 |
| 50.00 | 1.755 | 1.664 |
| 25.00 | 1.232 | 1.141 |
| 12.50 | 0.807 | 0.716 |
| 6.25 | 0.509 | 0.418 |
| 3.13 | 0.335 | 0.244 |
| 1.57 | 0.227 | 0.136 |
| 0.00 | 0.091 | 0.000 |

Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant ACTN3 and the recovery rates were calculated by comparing the measured value to the expected amount of ACTN3 in samples.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 80-97% | 88% |
| EDTA plasma(n=5) | 83-95% | 89% |
| Heparin plasma(n=5) | 81-95% | 88% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ACTN3 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 91-103% | 85-97% | 90-99% | 82-101% |
| EDTA plasma(n=5) | 85-94% | 87-101% | 82-93% | 97-106% |
| Heparin plasma(n=5) | 89-102% | 89-97% | 86-95% | 81-93% |