Overview
| Product name: | Human NT-ProCNP(N-Terminal Pro-C-Type Natriuretic Peptide) ELISA Kit |
| Reactivity: | Human |
| Alternative Names: | N-CNP |
| Assay Type: | Competitive Inhibition |
| Sensitivity: | 5.52 pg/mL |
| Standard: | 1000 pg/mL |
| Range: | 15.63-1000 pg/mL |
| Sample Type: | Serum, plasma, tissue homogenates and other biological fluids |
| Assay Length: | 2h |
| Research Area: | Cardiovascular biology;Hormone metabolism; |
| Test principle: | This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Human NT-ProCNP protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human NT-ProCNP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human NT-ProCNP in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 1000.00 | 0.199 | — |
| 500.00 | 0.385 | — |
| 250.00 | 0.567 | — |
| 125.00 | 0.895 | — |
| 62.50 | 1.168 | — |
| 31.25 | 1.537 | — |
| 15.63 | 1.624 | — |
| 0.00 | 2.028 | — |

Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant NT-ProCNP and the recovery rates were calculated by comparing the measured value to the expected amount of NT-ProCNP in samples.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 85-98% | 91% |
| EDTA plasma(n=5) | 78-90% | 84% |
| Heparin plasma(n=5) | 95-107% | 98% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of NT-ProCNP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 85-94% | 87-99% | 89-100% | 85-96% |
| EDTA plasma(n=5) | 86-95% | 93-103% | 85-94% | 87-101% |
| Heparin plasma(n=5) | 95-102% | 90-96% | 87-1028% | 85-97% |