Overview
| Product name: | Mouse I-PTH(IntactParathormone) ELISA Kit |
| Reactivity: | Mouse |
| Alternative Names: | iPTH; Intact Parathyroid Hormone; Parathormone; Parathyrin; PTH; Parathyroid Hormone |
| Assay Type: | Sandwich |
| Sensitivity: | 3.94 pg/mL |
| Standard: | 800 pg/mL |
| Detection Range: | 12.5-800 pg/mL |
| Sample Type: | serum, plasma and other biological fluids |
| Assay Length: | 3.5h |
| Research Area: | Metabolic pathway;Endocrinology;Hormone metabolism; |
| Test principle: | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse I-PTH. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse I-PTH. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse I-PTH, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse I-PTH in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 800.00 | 2.154 | 2.067 |
| 400.00 | 1.577 | 1.490 |
| 200.00 | 1.035 | 0.948 |
| 100.00 | 0.882 | 0.795 |
| 50.00 | 0.487 | 0.400 |
| 25.00 | 0.387 | 0.300 |
| 12.50 | 0.161 | 0.074 |
| 0.00 | 0.087 | 0.000 |

Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant I-PTH and the recovery rates were calculated by comparing the measured value to the expected amount of I-PTH in samples.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 78-95% | 86% |
| EDTA plasma(n=5) | 80-96% | 88% |
| Heparin plasma(n=5) | 80-92% | 86% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of I-PTH and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 85-94% | 95-103% | 87-101% | 82-90% |
| EDTA plasma(n=5) | 97-105% | 84-96% | 87-98% | 95-102% |
| Heparin plasma(n=5) | 88-96% | 85-96% | 93-102% | 95-104% |