1
/
of
1
ELK Biotechnology
SKU:ELK2427
Human PTH(Parathyroid Hormone) ELISA Kit
Human PTH(Parathyroid Hormone) ELISA Kit
Regular price
$458.00 USD
Regular price
Sale price
$458.00 USD
Unit price
/
per
Shipping calculated at checkout.
Couldn't load pickup availability
Human PTH(Parathyroid Hormone) ELISA Kit
Overview
| Product name: | Human I-PTH(IntactParathormone) ELISA Kit |
| Reactivity: | Human |
| Alternative Names: | iPTH; Intact Parathyroid Hormone; Parathormone; Parathyrin; PTH; Parathyroid Hormone |
| Assay Type: | Sandwich |
| Sensitivity: | 4.95 pg/mL |
| Standard: | 1000 pg/mL |
| Detection Range: | 15.63-1000 pg/mL |
| Sample Type: | serum, plasma and other biological fluids |
| Assay Length: | 3.5h |
| Research Area: | Metabolic pathway;Endocrinology;Hormone metabolism; |
| Test principle: | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human I-PTH. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human I-PTH. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human I-PTH, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human I-PTH in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 1000.00 | 1.989 | 1.900 |
| 500.00 | 1.633 | 1.544 |
| 250.00 | 1.121 | 1.032 |
| 125.00 | 0.726 | 0.637 |
| 62.50 | 0.529 | 0.440 |
| 31.25 | 0.322 | 0.233 |
| 15.63 | 0.252 | 0.163 |
| 0.00 | 0.089 | 0.000 |

Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant I-PTH and the recovery rates were calculated by comparing the measured value to the expected amount of I-PTH in samples.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 86-99% | 92% |
| EDTA plasma(n=5) | 80-95% | 87% |
| Heparin plasma(n=5) | 83-95% | 89% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of I-PTH and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 95-102% | 87-101% | 82-95% | 81-93% |
| EDTA plasma(n=5) | 85-92% | 79-96% | 95-102% | 87-98% |
| Heparin plasma(n=5) | 89-105% | 81-94% | 96-105% | 92-103% |
Share