Skip to product information
1 of 1

ELK Biotechnology

SKU:ELK1392

Rat IgM(Immunoglobulin M) ELISA Kit

Rat IgM(Immunoglobulin M) ELISA Kit

Regular price $376.00 USD
Regular price Sale price $376.00 USD
Sale Sold out
Shipping calculated at checkout.
Size
Sensitivity
Detection range

Rat IgM(Immunoglobulin M) ELISA Kit

Overview

Product name: Rat IgM(Immunoglobulin M) ELISA Kit
Reactivity: Rat
Alternative Names: IGHM; Immunoglobulin Heavy Constant Mu; Ig mu chain C region
Assay Type: Competitive Inhibition
Sensitivity: 97.3 ng/mL
Standard: 20000 ng/mL
Detection Range: 312.5-20000 ng/mL
Sample Type: serum, plasma and other biological fluids
Assay Length: 2h
Research Area: Infection immunity;Immune molecule;Hematology;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Rat IgM protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat IgM. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat IgM in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (ng/mL) OD Corrected OD
20000.00 0.175
10000.00 0.389
5000.00 0.655
2500.00 0.913
1250.00 1.253
625.00 1.596
312.50 1.761
0.00 2.211

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant IgM and the recovery rates were calculated by comparing the measured value to the expected amount of IgM in samples.
Matrix Recovery range Average
serum(n=5) 84-96% 90%
EDTA plasma(n=5) 96-107% 101%
Heparin plasma(n=5) 87-99% 92%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of IgM and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 82-94% 85-96% 78-90% 91-99%
EDTA plasma(n=5) 86-93% 91-105% 87-98% 99-102%
Heparin plasma(n=5) 95-104% 82-94% 86-96% 81-97%
View full details