1
/
of
1
ELK Biotechnology
SKU:ELK9387
General 25-OH-D(25 Hydroxy Vitamin D) ELISA Kit
General 25-OH-D(25 Hydroxy Vitamin D) ELISA Kit
Regular price
$376.00 USD
Regular price
Sale price
$376.00 USD
Unit price
/
per
Shipping calculated at checkout.
Couldn't load pickup availability
General 25-OH-D(25 Hydroxy Vitamin D) ELISA Kit
Overview
| Product name: | 25-OH-D(25 Hydroxy Vitamin D) ELISA Kit |
| Reactivity: | General |
| Alternative Names: | 25 Hydroxy Vitamin D; |
| Assay Type: | Competitive Inhibition |
| Sensitivity: | 0.91 ng/mL |
| Standard: | 200 ng/mL |
| Detection Range: | 3.13-200 ng/mL |
| Sample Type: | serum, plasma and other biological fluids |
| Assay Length: | 2h |
| Research Area: | Reproductive science;Genetic science;Nutrition metabolism;Bone metabolism; |
| Test principle: | This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with 25-OH-D protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to 25-OH-D. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of 25-OH-D in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 200.00 | 0.199 | — |
| 100.00 | 0.357 | — |
| 50.00 | 0.587 | — |
| 25.00 | 0.823 | — |
| 12.50 | 1.253 | — |
| 6.25 | 1.596 | — |
| 3.13 | 1.871 | — |
| 0.00 | 2.233 | — |

Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant 25-OH-D and the recovery rates were calculated by comparing the measured value to the expected amount of 25-OH-D in samples.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 82-94% | 88% |
| EDTA plasma(n=5) | 93-107% | 100% |
| Heparin plasma(n=5) | 95-107% | 101% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of 25-OH-D and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 95-102% | 98-106% | 87-98% | 83-95% |
| EDTA plasma(n=5) | 84-99% | 83-101% | 95-104% | 85-92% |
| Heparin plasma(n=5) | 97-103% | 87-98% | 95-102% | 81-103% |
Share