1
/
of
1
ELK Biotechnology
SKU:ELK9502
Human NEDD4-L(E3 ubiquitin-protein ligase NEDD4-like) ELISA Kit
Human NEDD4-L(E3 ubiquitin-protein ligase NEDD4-like) ELISA Kit
Regular price
$458.00 USD
Regular price
Sale price
$458.00 USD
Unit price
/
per
Shipping calculated at checkout.
Couldn't load pickup availability
Human NEDD4-L(E3 ubiquitin-protein ligase NEDD4-like) ELISA Kit
Overview
| Product name: | Human NEDD4-L(E3 ubiquitin-protein ligase NEDD4-like) ELISA Kit |
| Reactivity: | Human |
| Alternative Names: | NED4L;NEDD4 2 |
| Assay Type: | Sandwich |
| Sensitivity: | 0.119 ng/mL |
| Standard: | 20 ng/mL |
| Detection Range: | 0.32-20 ng/mL |
| Sample Type: | serum, plasma, tissue homogenates and other biological fluids |
| Assay Length: | 3.5h |
| Research Area: | Enzyme & Kinase; |
| Test principle: | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human NEDD4-L. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human NEDD4-L. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human NEDD4-L, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human NEDD4-L in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 20.00 | 2.266 | 2.179 |
| 10.00 | 1.675 | 1.588 |
| 5.00 | 1.169 | 1.082 |
| 2.50 | 0.896 | 0.809 |
| 1.25 | 0.559 | 0.472 |
| 0.63 | 0.357 | 0.270 |
| 0.32 | 0.175 | 0.088 |
| 0.00 | 0.087 | 0.000 |

Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant NEDD4-L and the recovery rates were calculated by comparing the measured value to the expected amount of NEDD4-L in samples.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 82-95% | 88% |
| EDTA plasma(n=5) | 82-95% | 88% |
| Heparin plasma(n=5) | 80-95% | 87% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of NEDD4-L and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 82-96% | 85-97% | 93-101% | 85-98% |
| EDTA plasma(n=5) | 90-101% | 92-103% | 81-99% | 94-106% |
| Heparin plasma(n=5) | 83-97% | 93-103% | 87-98% | 85-96% |
Share