{"product_id":"new-product-642093","title":"ELISA Kit for Oxytocin (OT)","description":"\u003cp\u003eEnzyme-linked immunosorbent assay for Antigen Detection.\u003c\/p\u003e\n\u003cp\u003eProduct No.\u003c\/p\u003e\n\u003cp\u003eCEB052Ge\u003c\/p\u003e\n\u003cp\u003eOrganism Species\u003c\/p\u003e\n\u003cp\u003ePan-species (General).\u003c\/p\u003e\n\u003cp\u003eSample Type\u003c\/p\u003e\n\u003cp\u003eSerum, plasma and other biological fluids\u003c\/p\u003e\n\u003cp\u003eTest Method\u003c\/p\u003e\n\u003cp\u003eCompetitive Inhibition\u003c\/p\u003e\n\u003cp\u003eAssay Length\u003c\/p\u003e\n\u003cp\u003e2h\u003c\/p\u003e\n\u003cp\u003eDetection Range\u003c\/p\u003e\n\u003cp\u003e12.35-1,000pg\/mL\u003c\/p\u003e\n\u003cp\u003eSensitivity\u003c\/p\u003e\n\u003cp\u003eThe minimum detectable dose of this kit is typically less than 5.27pg\/mL.\u003c\/p\u003e\n\u003cp\u003eUOM\u003c\/p\u003e\n\u003cp\u003e48T 96T 96T*5 96T*10 96T*100\u003c\/p\u003e\n\u003ch3\u003eSpecificity\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThis assay has high sensitivity and excellent specificity for detection of Oxytocin (OT).\u003cbr\u003eNo significant cross-reactivity or interference between Oxytocin (OT) and analogues was observed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eRecovery\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eMatrices listed below were spiked with certain level of Oxytocin (OT) and the recovery rates were calculated by comparing the measured value to the expected amount of Oxytocin (OT) in samples.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatrix\u003c\/td\u003e\n\u003ctd\u003eRecovery range (%)\u003c\/td\u003e\n\u003ctd\u003eAverage(%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eserum(n=5)\u003c\/td\u003e\n\u003ctd\u003e84-101\u003c\/td\u003e\n\u003ctd\u003e88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEDTA plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e88-101\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eheparin plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e84-91\u003c\/td\u003e\n\u003ctd\u003e87\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003ePrecision\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eIntra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Oxytocin (OT) were tested 20 times on one plate, respectively.\u003cbr\u003eInter-assay Precision (Precision between assays): 3 samples with low, middle and high level Oxytocin (OT) were tested on 3 different plates, 8 replicates in each plate.\u003cbr\u003eCV(%) = SD\/meanX100\u003cbr\u003eIntra-Assay: CV\u0026lt;10%\u003cbr\u003eInter-Assay: CV\u0026lt;12%\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinearity\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe linearity of the kit was assayed by testing samples spiked with appropriate concentration of Oxytocin (OT) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample\u003c\/td\u003e\n\u003ctd\u003e1:2\u003c\/td\u003e\n\u003ctd\u003e1:4\u003c\/td\u003e\n\u003ctd\u003e1:8\u003c\/td\u003e\n\u003ctd\u003e1:16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eserum(n=5)\u003c\/td\u003e\n\u003ctd\u003e79-97%\u003c\/td\u003e\n\u003ctd\u003e80-91%\u003c\/td\u003e\n\u003ctd\u003e79-94%\u003c\/td\u003e\n\u003ctd\u003e89-97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEDTA plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e89-96%\u003c\/td\u003e\n\u003ctd\u003e92-101%\u003c\/td\u003e\n\u003ctd\u003e89-103%\u003c\/td\u003e\n\u003ctd\u003e96-104%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eheparin plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e84-97%\u003c\/td\u003e\n\u003ctd\u003e89-96%\u003c\/td\u003e\n\u003ctd\u003e89-103%\u003c\/td\u003e\n\u003ctd\u003e96-104%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eStability\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.\u003cbr\u003eTo minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eReagents and materials provided\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"reagent_div\"\u003e\n\u003ctable class=\"reagent_table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first_tr\"\u003e\n\u003ctd\u003eReagents\u003c\/td\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003eReagents\u003c\/td\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated, ready to use 96-well strip plate\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003ePlate sealer for 96 wells\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1×20mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Reagent A\u003c\/td\u003e\n\u003ctd\u003e1×120µL\u003c\/td\u003e\n\u003ctd\u003eAssay Diluent A\u003c\/td\u003e\n\u003ctd\u003e1×12mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Reagent B\u003c\/td\u003e\n\u003ctd\u003e1×120µL\u003c\/td\u003e\n\u003ctd\u003eAssay Diluent B\u003c\/td\u003e\n\u003ctd\u003e1×12mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTMB Substrate\u003c\/td\u003e\n\u003ctd\u003e1×9mL\u003c\/td\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1×6mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWash Buffer (30 × concentrate)\u003c\/td\u003e\n\u003ctd\u003e1×20mL\u003c\/td\u003e\n\u003ctd\u003eInstruction manual\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAssay procedure summary\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003e1. Prepare all reagents, samples and standards;\u003cbr\u003e2. Add 50µL standard or sample to each well.\u003cbr\u003e    And then add 50µL prepared Detection Reagent A immediately.\u003cbr\u003e    Shake and mix. Incubate 1 hour at 37°C;\u003cbr\u003e3. Aspirate and wash 3 times;\u003cbr\u003e4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;\u003cbr\u003e5. Aspirate and wash 5 times;\u003cbr\u003e6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;\u003cbr\u003e7. Add 50µL Stop Solution. Read at 450 nm immediately.\u003c\/p\u003e\n\u003cdiv class=\"product_reference\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first_tr\"\u003e\n\u003ctd class=\"td_1\"\u003eMagazine\u003c\/td\u003e\n\u003ctd\u003eCitations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ Psychiatr Res.?\u003c\/td\u003e\n\u003ctd\u003eSex-specific associations between plasma oxytocin levels and schizotypal personality features in healthy individuals\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/24411593\" target=\"_blank\"\u003ePubmed:24411593\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFertility and Sterility\u003c\/td\u003e\n\u003ctd\u003eAdministration of atosiban in patients with endometriosis undergoing frozenâthawed embryo transfer: a prospective, randomized study\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/27143518\" target=\"_blank\"\u003ePubmed:27143518\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgress in neuro-psychopharmacology \u0026amp; biological psychiatry\u003c\/td\u003e\n\u003ctd\u003eIncreased oxytocin levels among abstinent heroin addicts: Association with aggressiveness, psychiatric symptoms and perceived childhood neglect.\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/28093220\" target=\"_blank\"\u003epubmed:28093220\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternational Journal of Clinical and Experimental Medicine\u003c\/td\u003e\n\u003ctd\u003eCan hypoxia enhance sexual arousal?-Molecular-biological analysis of the hypothalamus in male rats placed with oestrous female rats under hypoxic …\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"http:\/\/www.ijcem.com\/files\/ijcem0031358.pdf\" target=\"_blank\"\u003efiles:ijcem0031358.pdf\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFertility and Sterility\u003c\/td\u003e\n\u003ctd\u003eAdministration of atosiban in patients with endometriosis undergoing frozen–thawed embryo transfer: a prospective, randomized study\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/%2027143518\" target=\"_blank\"\u003epubmed:27143518\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBMC Med.\u003c\/td\u003e\n\u003ctd\u003eIntranasal oxytocin reduces provoked symptoms in female patients with posttraumatic stress disorder despite exerting sympathomimetic and positive chronotropic effects in a randomized controlled trial.\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/28209155\" target=\"_blank\"\u003epubmed:28209155\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePsychiatry Research\u003c\/td\u003e\n\u003ctd\u003ePlasma oxytocin levels in major depressive and bipolar II disorders\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/28865715\" target=\"_blank\"\u003epubmed:28865715\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBMC Medicine\u003c\/td\u003e\n\u003ctd\u003eIntranasal oxytocin reduces provoked symptoms in female patients with posttraumatic stress disorder despite exerting sympathomimetic and positive chronotropic effects in a randomized controlled trial\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/doi.org\/10.1186\/s12916-017-0801-0\" target=\"_blank\"\u003e10.1186:s12916-017-0801-0\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEUROPEAN ADDICTION RESEARCH\u003c\/td\u003e\n\u003ctd\u003eThe Association between the Level of Plasma Oxytocin and Craving among Former Heroin Users\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/29902803\" target=\"_blank\"\u003ePubmed:29902803\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASN Neuro .\u003c\/td\u003e\n\u003ctd\u003eInvolvement of Hyperpolarization-Activated Cyclic Nucleotide-Gated Channel 3 in Oxytocin Neuronal Activity in Lactating Rats With Pup Deprivation\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/32962418\/\" target=\"_blank\"\u003ePubmed: 32962418\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Journal of Integrative Medicine\u003c\/td\u003e\n\u003ctd\u003eEffects of transcutaneous electrical nerve stimulation applied at different frequencies during labor on hormone levels, labor pain perception, and anxiety: a randomized …\u003ca rel=\"nofollow\" href=\"https:\/\/www.cloud-clone.com\/products\/CEB052Ge.html\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ. Pers. Med\u003c\/td\u003e\n\u003ctd\u003ePredicting the Treatment Outcomes of Antidepressants Using a Deep Neural Network of Deep Learning in Drug-Naïve Major Depressive Patients\u003ca rel=\"nofollow\" href=\"https:\/\/www.mdpi.com\/1605540\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_relation\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first_tr\"\u003e\n\u003ctd class=\"td_1\"\u003eCatalog No.\u003c\/td\u003e\n\u003ctd class=\"td_2\"\u003eRelated products for research use of Pan-species (General) Organism species\u003c\/td\u003e\n\u003ctd class=\"td_3\"\u003eApplications (RESEARCH USE ONLY!)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPB052Ge11\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/CPB052Ge11.html\"\u003eBSA Conjugated Oxytocin (OT)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eImmunogen; SDS-PAGE; WB.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPB052Ge21\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/CPB052Ge21.html\"\u003eOVA Conjugated Oxytocin (OT)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eImmunogen; SDS-PAGE; WB.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAB052Ge01\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/PAB052Ge01.html\"\u003ePolyclonal Antibody to Oxytocin (OT)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eELISA, CLIA. \/ IHC-Fr, ICC, IP (predicted).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHEB052Ge\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/HEB052Ge.html\"\u003eHigh Sensitive ELISA Kit for Oxytocin (OT)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eEnzyme-linked immunosorbent assay for Antigen Detection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCEB052Ge\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/CEB052Ge.html\"\u003eELISA Kit for Oxytocin (OT)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eEnzyme-linked immunosorbent assay for Antigen Detection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLMB052Ge\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/LMB052Ge.html\"\u003eMagnetic Luminex Assay Kit for Oxytocin (OT) ,etc.\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnetic Luminex Assay for Antigen Detection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKSB052Ge11\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/KSB052Ge11.html\"\u003eELISA Kit DIY Materials for Oxytocin (OT)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMain materials for \"Do It (ELISA Kit) Yourself\".\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cloud-clone","offers":[{"title":"96T \/ The minimum detectable dose of this kit is typically less than 4.99pg\/mL \/ 12.35-1,000pg\/mL","offer_id":47592857075992,"sku":"CEB052Ge","price":646.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/5652\/1400\/products\/SE_BIG_96b0aab3-026e-4cdc-b350-a8adc3086191.jpg?v=1706252656","url":"https:\/\/danabiosci.com\/products\/new-product-642093","provider":"Dana Bioscience","version":"1.0","type":"link"}