{"product_id":"new-product-635663","title":"CLIA Kit for Tissue Polypeptide Specific Antigen (TPS)","description":"\u003cp\u003eChemiluminescent immunoassay for Antigen Detection.\u003c\/p\u003e\n\u003cp\u003eProduct No.\u003c\/p\u003e\n\u003cp\u003eSCB281Hu\u003c\/p\u003e\n\u003cp\u003eOrganism Species\u003c\/p\u003e\n\u003cp\u003eHomo sapiens (Human).\u003c\/p\u003e\n\u003cp\u003eSample Type\u003c\/p\u003e\n\u003cp\u003eSerum, plasma and other biological fluids.\u003c\/p\u003e\n\u003cp\u003eTest Method\u003c\/p\u003e\n\u003cp\u003eDouble-antibody Sandwich\u003c\/p\u003e\n\u003cp\u003eAssay Length\u003c\/p\u003e\n\u003cp\u003e2h, 40min\u003c\/p\u003e\n\u003cp\u003eDetection Range\u003c\/p\u003e\n\u003cp\u003e27.4-20,000pg\/mL\u003c\/p\u003e\n\u003cp\u003eSensitivity\u003c\/p\u003e\n\u003cp\u003eThe minimum detectable dose of this kit is typically less than 10.5pg\/mL.\u003c\/p\u003e\n\u003cp\u003eUOM\u003c\/p\u003e\n\u003cp\u003e48T 96T 96T*5 96T*10 96T*100\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eSpecificity\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis assay has high sensitivity and excellent specificity for detection of Tissue Polypeptide Specific Antigen (TPS).\u003cbr data-mce-fragment=\"1\"\u003eNo significant cross-reactivity or interference between Tissue Polypeptide Specific Antigen (TPS) and analogues was observed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eRecovery\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eMatrices listed below were spiked with certain level of recombinant Tissue Polypeptide Specific Antigen (TPS) and the recovery rates were calculated by comparing the measured value to the expected amount of Tissue Polypeptide Specific Antigen (TPS) in samples.\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMatrix\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRecovery range (%)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAverage(%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eserum(n=5)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e97-105\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEDTA plasma(n=5)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e83-95\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eheparin plasma(n=5)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e95-103\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003ePrecision\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIntra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Tissue Polypeptide Specific Antigen (TPS) were tested 20 times on one plate, respectively.\u003cbr data-mce-fragment=\"1\"\u003eInter-assay Precision (Precision between assays): 3 samples with low, middle and high level Tissue Polypeptide Specific Antigen (TPS) were tested on 3 different plates, 8 replicates in each plate.\u003cbr data-mce-fragment=\"1\"\u003eCV(%) = SD\/meanX100\u003cbr data-mce-fragment=\"1\"\u003eIntra-Assay: CV\u0026lt;10%\u003cbr data-mce-fragment=\"1\"\u003eInter-Assay: CV\u0026lt;12%\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eLinearity\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe linearity of the kit was assayed by testing samples spiked with appropriate concentration of Tissue Polypeptide Specific Antigen (TPS) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSample\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1:2\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1:4\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1:8\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1:16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eserum(n=5)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e80-104%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e80-94%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e93-103%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e91-105%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEDTA plasma(n=5)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e82-99%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e96-104%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e78-101%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e97-104%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eheparin plasma(n=5)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e78-92%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e93-101%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e89-103%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e86-101%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eStability\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.\u003cbr data-mce-fragment=\"1\"\u003eTo minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eReagents and materials provided\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"reagent_div\" data-mce-fragment=\"1\"\u003e\n\u003ctable class=\"reagent_table\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr class=\"first_tr\" data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eReagents\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eQuantity\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eReagents\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eQuantity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePre-coated, ready to use 96-well strip plate\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePlate sealer for 96 wells\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStandard\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e2\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×20mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eDetection Reagent A\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×120µL\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAssay Diluent A\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×12mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eDetection Reagent B\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×120µL\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAssay Diluent B\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×12mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSubstrate A\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×10mL\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSubstrate B\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×2mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWash Buffer (30 × concentrate)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×20mL\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eInstruction manual\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eAssay procedure summary\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1. Prepare all reagents, samples and standards;\u003cbr data-mce-fragment=\"1\"\u003e2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;\u003cbr data-mce-fragment=\"1\"\u003e3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;\u003cbr data-mce-fragment=\"1\"\u003e4. Aspirate and wash 3 times;\u003cbr data-mce-fragment=\"1\"\u003e5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;\u003cbr data-mce-fragment=\"1\"\u003e6. Aspirate and wash 5 times;\u003cbr data-mce-fragment=\"1\"\u003e7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;\u003cbr data-mce-fragment=\"1\"\u003e8. Read RLU value immediately.\u003c\/p\u003e\n\u003cdiv class=\"product_reference\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first_tr\"\u003e\n\u003ctd class=\"td_1\"\u003eMagazine\u003c\/td\u003e\n\u003ctd\u003eCitations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePancreatology\u003c\/td\u003e\n\u003ctd\u003eDiagnostic Validity of Serum Macrophage Inhibitor Cytokine and Tissue Polypeptide-Specific Antigen in Pancreatobiliary Diseases\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"http:\/\/content.karger.com\/produktedb\/produkte.asp?doi=328963\" target=\"_blank\"\u003eKarger: 328963\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRevista do Instituto de Medicina Tropical de São Paulo\u003c\/td\u003e\n\u003ctd\u003eVasoactive intestinal peptide degradation might influence Interleukin-17 expression in cardiac chagasic patients\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"http:\/\/www.scielo.br\/scielo.php?pid=S0036-46652018005000231\u0026amp;script=sci_arttext\" target=\"_blank\"\u003ePubmed: 30365640\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_relation\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first_tr\"\u003e\n\u003ctd class=\"td_1\"\u003eCatalog No.\u003c\/td\u003e\n\u003ctd class=\"td_2\"\u003eRelated products for research use of Homo sapiens (Human) Organism species\u003c\/td\u003e\n\u003ctd class=\"td_3\"\u003eApplications (RESEARCH USE ONLY!)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCB281Hu\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/SCB281Hu.html\"\u003eCLIA Kit for Tissue Polypeptide Specific Antigen (TPS)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eChemiluminescent immunoassay for Antigen Detection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLMB281Hu\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/LMB281Hu.html\"\u003eMagnetic Luminex Assay Kit for Tissue Polypeptide Specific Antigen (TPS) ,etc.\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnetic Luminex Assay for Antigen Detection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Cloud-clone","offers":[{"title":"96T \/ The minimum detectable dose of this kit is typically less than 10.5pg\/mL \/ 27.4-20,000pg\/mL","offer_id":47588528718104,"sku":"SCB281Hu","price":840.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/5652\/1400\/products\/SE_BIG_5231e3c1-be50-4b96-81bf-7219577951e8.jpg?v=1706201738","url":"https:\/\/danabiosci.com\/products\/new-product-635663","provider":"Dana Bioscience","version":"1.0","type":"link"}