{"product_id":"new-product-634846","title":"ELISA Kit for Hemoglobin (HB)","description":"\u003cp\u003eEnzyme-linked immunosorbent assay for Antigen Detection.\u003c\/p\u003e\n\u003cp\u003eProduct No.\u003c\/p\u003e\n\u003cp\u003eCEB409Rb\u003c\/p\u003e\n\u003cp\u003eOrganism Species\u003c\/p\u003e\n\u003cp\u003eOryctolagus cuniculus (Rabbit).\u003c\/p\u003e\n\u003cp\u003eSample Type\u003c\/p\u003e\n\u003cp\u003eSerum, plasma, erythrocyte lysates and other biological fluids\u003c\/p\u003e\n\u003cp\u003eTest Method\u003c\/p\u003e\n\u003cp\u003eCompetitive Inhibition\u003c\/p\u003e\n\u003cp\u003eAssay Length\u003c\/p\u003e\n\u003cp\u003e2h\u003c\/p\u003e\n\u003cp\u003eDetection Range\u003c\/p\u003e\n\u003cp\u003e1.23-100ug\/mL\u003c\/p\u003e\n\u003cp\u003eSensitivity\u003c\/p\u003e\n\u003cp\u003eThe minimum detectable dose of this kit is typically less than 0.55ug\/mL.\u003c\/p\u003e\n\u003cp\u003eUOM\u003c\/p\u003e\n\u003cp\u003e48T 96T 96T*5 96T*10 96T*100\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eSpecificity\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThis assay has high sensitivity and excellent specificity for detection of Hemoglobin (HB).\u003cbr\u003eNo significant cross-reactivity or interference between Hemoglobin (HB) and analogues was observed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eRecovery\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eMatrices listed below were spiked with certain level of recombinant Hemoglobin (HB) and the recovery rates were calculated by comparing the measured value to the expected amount of Hemoglobin (HB) in samples.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatrix\u003c\/td\u003e\n\u003ctd\u003eRecovery range (%)\u003c\/td\u003e\n\u003ctd\u003eAverage(%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eserum(n=5)\u003c\/td\u003e\n\u003ctd\u003e79-88\u003c\/td\u003e\n\u003ctd\u003e83\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEDTA plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e78-97\u003c\/td\u003e\n\u003ctd\u003e82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eheparin plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e91-105\u003c\/td\u003e\n\u003ctd\u003e96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003ePrecision\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eIntra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Hemoglobin (HB) were tested 20 times on one plate, respectively.\u003cbr\u003eInter-assay Precision (Precision between assays): 3 samples with low, middle and high level Hemoglobin (HB) were tested on 3 different plates, 8 replicates in each plate.\u003cbr\u003eCV(%) = SD\/meanX100\u003cbr\u003eIntra-Assay: CV\u0026lt;10%\u003cbr\u003eInter-Assay: CV\u0026lt;12%\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinearity\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe linearity of the kit was assayed by testing samples spiked with appropriate concentration of Hemoglobin (HB) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample\u003c\/td\u003e\n\u003ctd\u003e1:2\u003c\/td\u003e\n\u003ctd\u003e1:4\u003c\/td\u003e\n\u003ctd\u003e1:8\u003c\/td\u003e\n\u003ctd\u003e1:16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eserum(n=5)\u003c\/td\u003e\n\u003ctd\u003e82-91%\u003c\/td\u003e\n\u003ctd\u003e94-101%\u003c\/td\u003e\n\u003ctd\u003e78-98%\u003c\/td\u003e\n\u003ctd\u003e81-99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEDTA plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e87-94%\u003c\/td\u003e\n\u003ctd\u003e80-97%\u003c\/td\u003e\n\u003ctd\u003e93-102%\u003c\/td\u003e\n\u003ctd\u003e96-104%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eheparin plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e88-99%\u003c\/td\u003e\n\u003ctd\u003e91-98%\u003c\/td\u003e\n\u003ctd\u003e91-98%\u003c\/td\u003e\n\u003ctd\u003e79-101%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eStability\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.\u003cbr\u003eTo minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eReagents and materials provided\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"reagent_div\"\u003e\n\u003ctable class=\"reagent_table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first_tr\"\u003e\n\u003ctd\u003eReagents\u003c\/td\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003eReagents\u003c\/td\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated, ready to use 96-well strip plate\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003ePlate sealer for 96 wells\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1×20mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Reagent A\u003c\/td\u003e\n\u003ctd\u003e1×120µL\u003c\/td\u003e\n\u003ctd\u003eAssay Diluent A\u003c\/td\u003e\n\u003ctd\u003e1×12mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Reagent B\u003c\/td\u003e\n\u003ctd\u003e1×120µL\u003c\/td\u003e\n\u003ctd\u003eAssay Diluent B\u003c\/td\u003e\n\u003ctd\u003e1×12mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTMB Substrate\u003c\/td\u003e\n\u003ctd\u003e1×9mL\u003c\/td\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1×6mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWash Buffer (30 × concentrate)\u003c\/td\u003e\n\u003ctd\u003e1×20mL\u003c\/td\u003e\n\u003ctd\u003eInstruction manual\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAssay procedure summary\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003e1. Prepare all reagents, samples and standards;\u003cbr\u003e2. Add 50µL standard or sample to each well.\u003cbr\u003e    And then add 50µL prepared Detection Reagent A immediately.\u003cbr\u003e    Shake and mix. Incubate 1 hour at 37°C;\u003cbr\u003e3. Aspirate and wash 3 times;\u003cbr\u003e4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;\u003cbr\u003e5. Aspirate and wash 5 times;\u003cbr\u003e6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;\u003cbr\u003e7. Add 50µL Stop Solution. Read at 450 nm immediately.\u003c\/p\u003e\n\u003cdiv class=\"product_reference\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first_tr\"\u003e\n\u003ctd class=\"td_1\"\u003eMagazine\u003c\/td\u003e\n\u003ctd\u003eCitations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComparative Biochemistry and Physiology Part C: Toxicology \u0026amp;amp; Pharmacology\u003c\/td\u003e\n\u003ctd\u003eEffects of ectoine on behavioural, physiological and biochemical parameters of Daphnia magna\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/25460046\" target=\"_blank\"\u003ePubmed:25460046\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLoS One.\u003c\/td\u003e\n\u003ctd\u003eComparative Proteomics Identifies Host Immune System Proteins Affected by Infection with Mycobacterium bovis\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/27027307\" target=\"_blank\"\u003ePubmed:27027307\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParasites \u0026amp; Vectors\u003c\/td\u003e\n\u003ctd\u003eThe intracellular bacterium Anaplasma phagocytophilum selectively manipulates the levels of vertebrate host proteins in the tick vector Ixodes scapularis.\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/27561965\" target=\"_blank\"\u003epubmed:27561965\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProteomics. Clinical Applications\u003c\/td\u003e\n\u003ctd\u003eElevated levels of protein AMBP in cerebrospinal fluid of women with preeclampsia compared to normotensive pregnant women.\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/27615121\" target=\"_blank\"\u003epubmed:27615121\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolecular nutrition \u0026amp; food research\u003c\/td\u003e\n\u003ctd\u003eChicory inulin ameliorates type 2 diabetes mellitus and suppresses JNK and MAPK pathways in vivo and in vitro\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/28105758\" target=\"_blank\"\u003epubmed:28105758\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrontiers in Immunology\u003c\/td\u003e\n\u003ctd\u003eOxidized Hemoglobin Is Antigenic and Immunogenic in Lupus\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/28694810\" target=\"_blank\"\u003epubmed:28694810\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e新規人工酸素運搬体HemoAct を用いた脳虚血再灌流障害治療開発に関する研究\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/www.cloud-clone.com\/products\/CEB409Rb.html\" target=\"_blank\"\u003e:\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActa Neuropathologica Communications\u003c\/td\u003e\n\u003ctd\u003eMural cell-derived laminin-α5 plays a detrimental role in ischemic stroke\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/actaneurocomms.biomedcentral.com\/articles\/10.1186\/s40478-019-0676-8\" target=\"_blank\"\u003ePubmed: 30777135\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAngiogenesis\u003c\/td\u003e\n\u003ctd\u003eDecylubiquinone suppresses breast cancer growth and metastasis by inhibiting angiogenesis via the ROS\/p53\/BAI1 signaling pathway\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/32020421\/\" target=\"_blank\"\u003ePubmed: 32020421\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFood Bioscience\u003c\/td\u003e\n\u003ctd\u003eWater-extractable zinc protoporphyrin IX in Parma ham predominantly exists as complexes with hemoglobin and myoglobin\u003ca rel=\"nofollow\" href=\"https:\/\/www.sciencedirect.com\/science\/article\/pii\/S2212429220312086\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotochem Photobiol\u003c\/td\u003e\n\u003ctd\u003eEffects of Human Serum Albumin on the Fluorescence Intensity and Tumor Imaging Properties of IR‐780 Dye\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/34687567\/\" target=\"_blank\"\u003e34687567\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_relation\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first_tr\"\u003e\n\u003ctd class=\"td_1\"\u003eCatalog No.\u003c\/td\u003e\n\u003ctd class=\"td_2\"\u003eRelated products for research use of Oryctolagus cuniculus (Rabbit) Organism species\u003c\/td\u003e\n\u003ctd class=\"td_3\"\u003eApplications (RESEARCH USE ONLY!)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNPB409Rb01\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/NPB409Rb01.html\"\u003eNative Hemoglobin (HB)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive Control; Immunogen; SDS-PAGE; WB.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAB409Rb01\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/PAB409Rb01.html\"\u003ePolyclonal Antibody to Hemoglobin (HB)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWB; IHC; ICC; IP.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAB409Rb52\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/PAB409Rb52.html\"\u003ePolyclonal Antibody to Hemoglobin (HB)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWB; IHC; ICC; IP.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAB409Rb51\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/PAB409Rb51.html\"\u003ePolyclonal Antibody to Hemoglobin (HB)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWB; IHC; ICC; IP.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLAB409Rb71\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/LAB409Rb71.html\"\u003eBiotin-Linked Polyclonal Antibody to Hemoglobin (HB)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWB; IHC; ICC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCEB409Rb\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/CEB409Rb.html\"\u003eELISA Kit for Hemoglobin (HB)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eEnzyme-linked immunosorbent assay for Antigen Detection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLMB409Rb\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/LMB409Rb.html\"\u003eMagnetic Luminex Assay Kit for Hemoglobin (HB) ,etc.\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnetic Luminex Assay for Antigen Detection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKSB409Rb11\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/KSB409Rb11.html\"\u003eELISA Kit DIY Materials for Hemoglobin (HB)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMain materials for \"Do It (ELISA Kit) Yourself\".\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cloud-clone","offers":[{"title":"96T \/ The minimum detectable dose of this kit is typically less than 0.53ug\/mL \/ 1.23-100ug\/mL","offer_id":47583883231512,"sku":"CEB409Rb","price":760.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/5652\/1400\/products\/SE_BIG_ccad4b1a-f6f5-4f5f-960d-d4f31296d97c.jpg?v=1706161114","url":"https:\/\/danabiosci.com\/products\/new-product-634846","provider":"Dana Bioscience","version":"1.0","type":"link"}