{"product_id":"new-product-617686","title":"Magnetic Luminex Assay Kit for 8-Epi Prostaglandin F2 Alpha (8-epi-PGF2a, 8-iso-PGF2alpha, 8-iso-PGF2a) ,etc.","description":"\u003cp data-mce-fragment=\"1\"\u003eProduct No.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eLMA701Ge\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eOrganism Species\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePan-species (General).\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSample Type\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSerum, plasma and other biological fluids\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eTest Method\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eCompetitive Inhibition\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAssay Length\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1.5h\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eDetection Range\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1.95-2000pg\/mL\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSensitivity\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe minimum detectable dose of this kit is typically less than 0.65 pg\/mL.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eUOM\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cdiv class=\"product\"\u003e\n\u003cdiv class=\"product_left\"\u003e\n\u003ch3\u003eSpecificity\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThis assay has high sensitivity and excellent specificity for detection of 8-Epi Prostaglandin F2 Alpha (8-epi-PGF2a, 8-iso-PGF2alpha, 8-iso-PGF2a) ,etc..\u003cbr\u003eNo significant cross-reactivity or interference between 8-Epi Prostaglandin F2 Alpha (8-epi-PGF2a, 8-iso-PGF2alpha, 8-iso-PGF2a) ,etc. and analogues was observed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eRecovery\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eMatrices listed below were spiked with certain level of 8-Epi Prostaglandin F2 Alpha (8-epi-PGF2a, 8-iso-PGF2alpha, 8-iso-PGF2a) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of 8-Epi Prostaglandin F2 Alpha (8-epi-PGF2a, 8-iso-PGF2alpha, 8-iso-PGF2a) ,etc. in samples.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatrix\u003c\/td\u003e\n\u003ctd\u003eRecovery range (%)\u003c\/td\u003e\n\u003ctd\u003eAverage(%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eserum(n=5)\u003c\/td\u003e\n\u003ctd\u003e80-99\u003c\/td\u003e\n\u003ctd\u003e94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEDTA plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e80-94\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eheparin plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e78-95\u003c\/td\u003e\n\u003ctd\u003e89\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esodium citrate plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e79-88\u003c\/td\u003e\n\u003ctd\u003e81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003ePrecision\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eIntra-assay Precision (Precision within an assay): 3 samples with low, middle and high level 8-Epi Prostaglandin F2 Alpha (8-epi-PGF2a, 8-iso-PGF2alpha, 8-iso-PGF2a) ,etc. were tested 20 times on one plate, respectively.\u003cbr\u003eInter-assay Precision (Precision between assays): 3 samples with low, middle and high level 8-Epi Prostaglandin F2 Alpha (8-epi-PGF2a, 8-iso-PGF2alpha, 8-iso-PGF2a) ,etc. were tested on 3 different plates, 8 replicates in each plate.\u003cbr\u003eCV(%) = SD\/meanX100\u003cbr\u003eIntra-Assay: CV\u0026lt;10%\u003cbr\u003eInter-Assay: CV\u0026lt;12%\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinearity\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe linearity of the kit was assayed by testing samples spiked with appropriate concentration of 8-Epi Prostaglandin F2 Alpha (8-epi-PGF2a, 8-iso-PGF2alpha, 8-iso-PGF2a) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample\u003c\/td\u003e\n\u003ctd\u003e1:2\u003c\/td\u003e\n\u003ctd\u003e1:4\u003c\/td\u003e\n\u003ctd\u003e1:8\u003c\/td\u003e\n\u003ctd\u003e1:16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eserum(n=5)\u003c\/td\u003e\n\u003ctd\u003e80-96%\u003c\/td\u003e\n\u003ctd\u003e88-104%\u003c\/td\u003e\n\u003ctd\u003e94-102%\u003c\/td\u003e\n\u003ctd\u003e91-98%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEDTA plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e97-105%\u003c\/td\u003e\n\u003ctd\u003e95-105%\u003c\/td\u003e\n\u003ctd\u003e96-103%\u003c\/td\u003e\n\u003ctd\u003e97-105%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eheparin plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e94-105%\u003c\/td\u003e\n\u003ctd\u003e96-103%\u003c\/td\u003e\n\u003ctd\u003e78-94%\u003c\/td\u003e\n\u003ctd\u003e88-95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esodium citrate plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e97-105%\u003c\/td\u003e\n\u003ctd\u003e82-101%\u003c\/td\u003e\n\u003ctd\u003e78-94%\u003c\/td\u003e\n\u003ctd\u003e80-99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eStability\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.\u003cbr\u003eTo minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eReagents and materials provided\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"reagent_div\"\u003e\n\u003ctable class=\"reagent_table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first_tr\"\u003e\n\u003ctd\u003eReagents\u003c\/td\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003eReagents\u003c\/td\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e96-well plate\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003ePlate sealer for 96 wells\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-Mixed Standard\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1×20mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-Mixed Magnetic beads (22#:8-epi-PGF2a, 8-iso-PGF2alpha, 8-iso-PGF2a)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eAnalysis buffer\u003c\/td\u003e\n\u003ctd\u003e1×20mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-Mixed Detection Reagent A\u003c\/td\u003e\n\u003ctd\u003e1×120μL\u003c\/td\u003e\n\u003ctd\u003eAssay Diluent A\u003c\/td\u003e\n\u003ctd\u003e1×12mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Reagent B (PE-SA)\u003c\/td\u003e\n\u003ctd\u003e1×120μL\u003c\/td\u003e\n\u003ctd\u003eAssay Diluent B\u003c\/td\u003e\n\u003ctd\u003e1×12mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath Fluid\u003c\/td\u003e\n\u003ctd\u003e1×10mL\u003c\/td\u003e\n\u003ctd\u003eWash Buffer (30 × concentrate)\u003c\/td\u003e\n\u003ctd\u003e1×20mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstruction manual\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAssay procedure summary\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003e1. Preparation of standards, reagents and samples before the experiment;\u003cbr\u003e2. Add 50μL standard or sample to each well,\u003cbr\u003e    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;\u003cbr\u003e3. Wash plate on magnetic frame for three times;\u003cbr\u003e4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;\u003cbr\u003e5. Wash plate on magnetic frame for three times;\u003cbr\u003e6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul class=\"product_increment\"\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_reference\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first_tr\"\u003e\n\u003ctd class=\"td_1\"\u003eMagazine\u003c\/td\u003e\n\u003ctd\u003eCitations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternational Journal of Clinical and Experimental Medicine\u003c\/td\u003e\n\u003ctd\u003eRelationships between glucose fluctuations and oxidative stress in short duration type 2 diabetes treated with sensor-augmented insulin pump.\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"http:\/\/www.ijcem.com\/files\/ijcem0034423.pdf\" target=\"_blank\"\u003eISSN:1940-5901\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBMC Veterinary Research\u003c\/td\u003e\n\u003ctd\u003eHormonal and metabolic indicators before and after farrowing in sows affected with postpartum dysgalactia syndrome\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/bmcvetres.biomedcentral.com\/articles\/10.1186\/s12917-018-1649-z\" target=\"_blank\"\u003ePubmed: 30404636\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_relation\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first_tr\"\u003e\n\u003ctd class=\"td_1\"\u003eCatalog No.\u003c\/td\u003e\n\u003ctd class=\"td_2\"\u003eRelated products for research use of Pan-species (General) Organism species\u003c\/td\u003e\n\u003ctd class=\"td_3\"\u003eApplications (RESEARCH USE ONLY!)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCEA701Ge\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/CEA701Ge.html\"\u003eELISA Kit for 8-Epi Prostaglandin F2 Alpha (8-epi-PGF2a, 8-iso-PGF2alpha, 8-iso-PGF2a)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eEnzyme-linked immunosorbent assay for Antigen Detection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLMA701Ge\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/LMA701Ge.html\"\u003eMagnetic Luminex Assay Kit for 8-Epi Prostaglandin F2 Alpha (8-epi-PGF2a, 8-iso-PGF2alpha, 8-iso-PGF2a) ,etc.\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnetic Luminex Assay for Antigen Detection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"more_info\"\u003e\u003c\/div\u003e","brand":"Cloud-clone","offers":[{"title":"1.95-2000pg\/mL \/ 96T \/ typically less than 0.65 pg\/mL","offer_id":47568236577048,"sku":"LMA701Ge","price":955.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/5652\/1400\/products\/LMA701Ge_6e845d15-481f-40a8-bc51-0d9dc0ec7544.jpg?v=1705968676","url":"https:\/\/danabiosci.com\/products\/new-product-617686","provider":"Dana Bioscience","version":"1.0","type":"link"}