{"product_id":"new-product-616138","title":"Magnetic Luminex Assay Kit for Apolipoprotein M (APOM) ,etc.","description":"\u003cp data-mce-fragment=\"1\"\u003eProduct No.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eLMC299Hu\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eOrganism Species\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eHomo sapiens (Human).\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSample Type\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSerum, plasma, tissue homogenates and other biological fluids\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eTest Method\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eDouble-antibody Sandwich\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAssay Length\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3.5h\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eDetection Range\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.1-100ng\/mL\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSensitivity\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe minimum detectable dose of this kit is typically less than 0.033 ng\/mL.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eUOM\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cdiv class=\"product_left\"\u003e\n\u003ch3\u003eSpecificity\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThis assay has high sensitivity and excellent specificity for detection of Apolipoprotein M (APOM) ,etc..\u003cbr\u003eNo significant cross-reactivity or interference between Apolipoprotein M (APOM) ,etc. and analogues was observed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eRecovery\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eMatrices listed below were spiked with certain level of recombinant Apolipoprotein M (APOM) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Apolipoprotein M (APOM) ,etc. in samples.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatrix\u003c\/td\u003e\n\u003ctd\u003eRecovery range (%)\u003c\/td\u003e\n\u003ctd\u003eAverage(%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eserum(n=5)\u003c\/td\u003e\n\u003ctd\u003e81-96\u003c\/td\u003e\n\u003ctd\u003e89\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEDTA plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e89-97\u003c\/td\u003e\n\u003ctd\u003e92\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eheparin plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e88-99\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003ePrecision\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eIntra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Apolipoprotein M (APOM) ,etc. were tested 20 times on one plate, respectively.\u003cbr\u003eInter-assay Precision (Precision between assays): 3 samples with low, middle and high level Apolipoprotein M (APOM) ,etc. were tested on 3 different plates, 8 replicates in each plate.\u003cbr\u003eCV(%) = SD\/meanX100\u003cbr\u003eIntra-Assay: CV\u0026lt;10%\u003cbr\u003eInter-Assay: CV\u0026lt;12%\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinearity\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe linearity of the kit was assayed by testing samples spiked with appropriate concentration of Apolipoprotein M (APOM) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample\u003c\/td\u003e\n\u003ctd\u003e1:2\u003c\/td\u003e\n\u003ctd\u003e1:4\u003c\/td\u003e\n\u003ctd\u003e1:8\u003c\/td\u003e\n\u003ctd\u003e1:16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eserum(n=5)\u003c\/td\u003e\n\u003ctd\u003e79-103%\u003c\/td\u003e\n\u003ctd\u003e92-105%\u003c\/td\u003e\n\u003ctd\u003e98-105%\u003c\/td\u003e\n\u003ctd\u003e81-95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEDTA plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e79-103%\u003c\/td\u003e\n\u003ctd\u003e98-105%\u003c\/td\u003e\n\u003ctd\u003e79-102%\u003c\/td\u003e\n\u003ctd\u003e87-96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eheparin plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e83-104%\u003c\/td\u003e\n\u003ctd\u003e89-102%\u003c\/td\u003e\n\u003ctd\u003e97-104%\u003c\/td\u003e\n\u003ctd\u003e80-89%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eStability\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.\u003cbr\u003eTo minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eReagents and materials provided\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"reagent_div\"\u003e\n\u003ctable class=\"reagent_table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first_tr\"\u003e\n\u003ctd\u003eReagents\u003c\/td\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003eReagents\u003c\/td\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e96-well plate\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003ePlate sealer for 96 wells\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-Mixed Standard\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1×20mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-Mixed Magnetic beads (22#:APOM)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eAnalysis buffer\u003c\/td\u003e\n\u003ctd\u003e1×20mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-Mixed Detection Reagent A\u003c\/td\u003e\n\u003ctd\u003e1×120μL\u003c\/td\u003e\n\u003ctd\u003eAssay Diluent A\u003c\/td\u003e\n\u003ctd\u003e1×12mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Reagent B (PE-SA)\u003c\/td\u003e\n\u003ctd\u003e1×120μL\u003c\/td\u003e\n\u003ctd\u003eAssay Diluent B\u003c\/td\u003e\n\u003ctd\u003e1×12mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath Fluid\u003c\/td\u003e\n\u003ctd\u003e1×10mL\u003c\/td\u003e\n\u003ctd\u003eWash Buffer (30 × concentrate)\u003c\/td\u003e\n\u003ctd\u003e1×20mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstruction manual\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAssay procedure summary\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003e1. Preparation of standards, reagents and samples before the experiment;\u003cbr\u003e2. Add 100μL standard or sample to each well,\u003cbr\u003e    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;\u003cbr\u003e3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;\u003cbr\u003e4. Wash plate on magnetic frame for three times;\u003cbr\u003e5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;\u003cbr\u003e6. Wash plate on magnetic frame for three times;\u003cbr\u003e7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_reference\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first_tr\"\u003e\n\u003ctd class=\"td_1\"\u003eMagazine\u003c\/td\u003e\n\u003ctd\u003eCitations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJoint Bone Spine\u003c\/td\u003e\n\u003ctd\u003eApolipoprotein m (APOM) levels and APOM rs805297 G\/T polymorphism are associated with increased risk ofrheumatoid arthritis\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/23660425\" target=\"_blank\"\u003ePubmed: 23660425\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApoptosis\u003c\/td\u003e\n\u003ctd\u003eThe miR-573\/apoM\/Bcl2A1-dependent signal transduction pathway is essential for hepatocyte apoptosis and hepatocarcinogenesis\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/26201458\" target=\"_blank\"\u003ePubMed: 26201458\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLipids in Health and Disease\u003c\/td\u003e\n\u003ctd\u003eEffects of hyperlipidaemia on plasma apolipoprotein M levels in patients with type 2 diabetes mellitus: an independent case–control study\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/27633510\" target=\"_blank\"\u003epubmed:27633510\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLipids in Health and Disease\u003c\/td\u003e\n\u003ctd\u003eA single-nucleotide polymorphism C-724 \/del in the proter region of the apolipoprotein M gene is associated with type 2 diabetes mellitus\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/27576735\" target=\"_blank\"\u003epubmed:27576735\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eclinica chimica acta\u003c\/td\u003e\n\u003ctd\u003eApoM\/HDL-C and apoM\/apoA-I ratios are indicators of diabetic nephropathy in healthy controls and type 2 diabetes mellitus.\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/28073663\" target=\"_blank\"\u003epubmed:28073663\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternational Journal of Clinical and Experimental Pathology\u003c\/td\u003e\n\u003ctd\u003eLevel of serum apolipoprotein m and its diagnostic significance in inflammatory bowel disease\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"http:\/\/www.ijcep.com\/files\/ijcep0033416.pdf\" target=\"_blank\"\u003efiles:ijcep0033416.pdf\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScandinavian Journal of Medicine \u0026amp; Science in Sports\u003c\/td\u003e\n\u003ctd\u003eEndurance training selectively increases HDL-bound sphingosine-1-phosphate in the plasma\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/28493600\" target=\"_blank\"\u003epubmed:28493600\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eINTERNATIONAL JOURNAL OF BIOCHEMISTRY \u0026amp; CELL BIOLOGY\u003c\/td\u003e\n\u003ctd\u003eHDL-S1P Protects Endothelial Function and Reduces Lung Injury During Sepsis in vivo and in vitro\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/32750426\/\" target=\"_blank\"\u003ePubmed: 32750426\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBiology-Basel\u003c\/td\u003e\n\u003ctd\u003eBiomechanical Properties of Blood Plasma Extracellular Vesicles Revealed by Atomic Force Microscopy\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/33374530\" target=\"_blank\"\u003e33374530\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eresearchsquare\u003c\/td\u003e\n\u003ctd\u003eApolipoprotein M in High Density Lipoprotein Protects Against Astrocyte Apoptosis Induced By Ischemic Insult Via Sphingosine 1-Phosphate Signaling\u003ca rel=\"nofollow\" href=\"https:\/\/www.researchsquare.com\/article\/rs-216278\/latest.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_relation\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first_tr\"\u003e\n\u003ctd class=\"td_1\"\u003eCatalog No.\u003c\/td\u003e\n\u003ctd class=\"td_2\"\u003eRelated products for research use of Homo sapiens (Human) Organism species\u003c\/td\u003e\n\u003ctd class=\"td_3\"\u003eApplications (RESEARCH USE ONLY!)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRPC299Hu01\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/RPC299Hu01.html\"\u003eRecombinant Apolipoprotein M (APOM)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive Control; Immunogen; SDS-PAGE; WB.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAC299Hu01\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/PAC299Hu01.html\"\u003ePolyclonal Antibody to Apolipoprotein M (APOM)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWB; IHC; ICC; IP.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLAC299Hu71\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/LAC299Hu71.html\"\u003eBiotin-Linked Polyclonal Antibody to Apolipoprotein M (APOM)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWB; IHC; ICC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLAC299Hu81\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/LAC299Hu81.html\"\u003eFITC-Linked Polyclonal Antibody to Apolipoprotein M (APOM)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWB; IHC; ICC; IF.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAC299Hu21\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/MAC299Hu21.html\"\u003eMonoclonal Antibody to Apolipoprotein M (APOM)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWB; IHC; ICC; IP.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAC299Hu22\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/MAC299Hu22.html\"\u003eMonoclonal Antibody to Apolipoprotein M (APOM)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWB; IHC; ICC; IP.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEC299Hu\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/SEC299Hu.html\"\u003eELISA Kit for Apolipoprotein M (APOM)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eEnzyme-linked immunosorbent assay for Antigen Detection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHEC299Hu\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/HEC299Hu.html\"\u003eHigh Sensitive ELISA Kit for Apolipoprotein M (APOM)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eEnzyme-linked immunosorbent assay for Antigen Detection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLMC299Hu\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/LMC299Hu.html\"\u003eMagnetic Luminex Assay Kit for Apolipoprotein M (APOM) ,etc.\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnetic Luminex Assay for Antigen Detection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Cloud-clone","offers":[{"title":"0.1-100ng\/mL \/ 96T \/ typically less than 0.033 ng\/mL","offer_id":47567484027160,"sku":"LMC299Hu","price":840.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/5652\/1400\/products\/LMC299Hu_950a96f3-7687-4651-b6c4-bec42d1b3755.jpg?v=1705959211","url":"https:\/\/danabiosci.com\/products\/new-product-616138","provider":"Dana Bioscience","version":"1.0","type":"link"}