{"product_id":"new-product-614017","title":"Magnetic Luminex Assay Kit for Mitochondrial Uncoupling Protein 2 (UCP2) ,etc.","description":"\u003cp data-mce-fragment=\"1\"\u003eProduct No.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eLMC586Hu\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eOrganism Species\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eHomo sapiens (Human).\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSample Type\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eTissue homogenates, cell lysates and other biological fluids\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eTest Method\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eDouble-antibody Sandwich\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAssay Length\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3.5h\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eDetection Range\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.01-10ng\/mL\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSensitivity\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe minimum detectable dose of this kit is typically less than 0.003 ng\/mL.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eUOM\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cdiv class=\"product_left\"\u003e\n\u003ch3\u003eSpecificity\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThis assay has high sensitivity and excellent specificity for detection of Mitochondrial Uncoupling Protein 2 (UCP2) ,etc..\u003cbr\u003eNo significant cross-reactivity or interference between Mitochondrial Uncoupling Protein 2 (UCP2) ,etc. and analogues was observed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eRecovery\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eMatrices listed below were spiked with certain level of recombinant Mitochondrial Uncoupling Protein 2 (UCP2) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Mitochondrial Uncoupling Protein 2 (UCP2) ,etc. in samples.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatrix\u003c\/td\u003e\n\u003ctd\u003eRecovery range (%)\u003c\/td\u003e\n\u003ctd\u003eAverage(%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eserum(n=5)\u003c\/td\u003e\n\u003ctd\u003e85-101\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEDTA plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e81-88\u003c\/td\u003e\n\u003ctd\u003e84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eheparin plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e82-91\u003c\/td\u003e\n\u003ctd\u003e87\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003ePrecision\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eIntra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mitochondrial Uncoupling Protein 2 (UCP2) ,etc. were tested 20 times on one plate, respectively.\u003cbr\u003eInter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mitochondrial Uncoupling Protein 2 (UCP2) ,etc. were tested on 3 different plates, 8 replicates in each plate.\u003cbr\u003eCV(%) = SD\/meanX100\u003cbr\u003eIntra-Assay: CV\u0026lt;10%\u003cbr\u003eInter-Assay: CV\u0026lt;12%\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinearity\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mitochondrial Uncoupling Protein 2 (UCP2) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample\u003c\/td\u003e\n\u003ctd\u003e1:2\u003c\/td\u003e\n\u003ctd\u003e1:4\u003c\/td\u003e\n\u003ctd\u003e1:8\u003c\/td\u003e\n\u003ctd\u003e1:16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eserum(n=5)\u003c\/td\u003e\n\u003ctd\u003e88-95%\u003c\/td\u003e\n\u003ctd\u003e98-105%\u003c\/td\u003e\n\u003ctd\u003e93-101%\u003c\/td\u003e\n\u003ctd\u003e84-99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEDTA plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e84-99%\u003c\/td\u003e\n\u003ctd\u003e90-99%\u003c\/td\u003e\n\u003ctd\u003e83-98%\u003c\/td\u003e\n\u003ctd\u003e78-105%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eheparin plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e90-104%\u003c\/td\u003e\n\u003ctd\u003e80-94%\u003c\/td\u003e\n\u003ctd\u003e96-104%\u003c\/td\u003e\n\u003ctd\u003e78-104%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eStability\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.\u003cbr\u003eTo minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eReagents and materials provided\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"reagent_div\"\u003e\n\u003ctable class=\"reagent_table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first_tr\"\u003e\n\u003ctd\u003eReagents\u003c\/td\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003eReagents\u003c\/td\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e96-well plate\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003ePlate sealer for 96 wells\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-Mixed Standard\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1×20mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-Mixed Magnetic beads (22#:UCP2)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eAnalysis buffer\u003c\/td\u003e\n\u003ctd\u003e1×20mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-Mixed Detection Reagent A\u003c\/td\u003e\n\u003ctd\u003e1×120μL\u003c\/td\u003e\n\u003ctd\u003eAssay Diluent A\u003c\/td\u003e\n\u003ctd\u003e1×12mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Reagent B (PE-SA)\u003c\/td\u003e\n\u003ctd\u003e1×120μL\u003c\/td\u003e\n\u003ctd\u003eAssay Diluent B\u003c\/td\u003e\n\u003ctd\u003e1×12mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath Fluid\u003c\/td\u003e\n\u003ctd\u003e1×10mL\u003c\/td\u003e\n\u003ctd\u003eWash Buffer (30 × concentrate)\u003c\/td\u003e\n\u003ctd\u003e1×20mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstruction manual\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAssay procedure summary\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003e1. Preparation of standards, reagents and samples before the experiment;\u003cbr\u003e2. Add 100μL standard or sample to each well,\u003cbr\u003e    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;\u003cbr\u003e3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;\u003cbr\u003e4. Wash plate on magnetic frame for three times;\u003cbr\u003e5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;\u003cbr\u003e6. Wash plate on magnetic frame for three times;\u003cbr\u003e7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_reference\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first_tr\"\u003e\n\u003ctd class=\"td_1\"\u003eMagazine\u003c\/td\u003e\n\u003ctd\u003eCitations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStem Cells\u003c\/td\u003e\n\u003ctd\u003eFM19G11 Favors Spinal Cord Injury Regeneration and Stem Cell Self-Renewal by Mitochondrial Uncoupling and Glucose Metabolism Induction\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/22865656\" target=\"_blank\"\u003ePubMed: 22865656\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFood Research International\u003c\/td\u003e\n\u003ctd\u003eA 4-week consumption of medium roast and dark roast coffees affects parameters of energy status in healthy subjects\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"http:\/\/www.sciencedirect.com\/science\/article\/pii\/S0963996914002403\" target=\"_blank\"\u003eSciencedirect:S0963996914002403\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe Journal of Maternal-Fetal \u0026amp; Neonatal Medicine\u003c\/td\u003e\n\u003ctd\u003eThe effect of delivery type on uncoupling protein-2 levels\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/26479203\" target=\"_blank\"\u003ePubMed: 26479203\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLife Sciences\u003c\/td\u003e\n\u003ctd\u003eVitamin C and E chronic supplementation differentially affect hepatic insulin signaling in rats\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/29291420\" target=\"_blank\"\u003ePubmed:29291420\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eREPRODUCTIVE TOXICOLOGY\u003c\/td\u003e\n\u003ctd\u003eDose-dependent reproductive toxicity of sodium benzoate in male rats: Inflammation, oxidative stress and apoptosis\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/32911041\/\" target=\"_blank\"\u003ePubmed: 32911041\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTissue Cell\u003c\/td\u003e\n\u003ctd\u003eVitamin B12 ameliorate Tramadol-induced oxidative stress, endocrine imbalance, apoptosis and NO\/iNOS\/NF-κB expression in Sprague Dawley through regulatory …\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/34923198\/\" target=\"_blank\"\u003e34923198\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_relation\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first_tr\"\u003e\n\u003ctd class=\"td_1\"\u003eCatalog No.\u003c\/td\u003e\n\u003ctd class=\"td_2\"\u003eRelated products for research use of Homo sapiens (Human) Organism species\u003c\/td\u003e\n\u003ctd class=\"td_3\"\u003eApplications (RESEARCH USE ONLY!)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRPC586Hu01\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/RPC586Hu01.html\"\u003eRecombinant Mitochondrial Uncoupling Protein 2 (UCP2)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive Control; Immunogen; SDS-PAGE; WB.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAC586Hu01\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/PAC586Hu01.html\"\u003ePolyclonal Antibody to Mitochondrial Uncoupling Protein 2 (UCP2)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWB; IHC; ICC; IP.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLAC586Hu71\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/LAC586Hu71.html\"\u003eBiotin-Linked Polyclonal Antibody to Mitochondrial Uncoupling Protein 2 (UCP2)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWB; IHC; ICC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAC586Hu22\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/MAC586Hu22.html\"\u003eMonoclonal Antibody to Mitochondrial Uncoupling Protein 2 (UCP2)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWB,IHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAC586Hu21\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/MAC586Hu21.html\"\u003eMonoclonal Antibody to Mitochondrial Uncoupling Protein 2 (UCP2)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eIHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEC586Hu\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/SEC586Hu.html\"\u003eELISA Kit for Mitochondrial Uncoupling Protein 2 (UCP2)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eEnzyme-linked immunosorbent assay for Antigen Detection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLMC586Hu\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/LMC586Hu.html\"\u003eMagnetic Luminex Assay Kit for Mitochondrial Uncoupling Protein 2 (UCP2) ,etc.\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnetic Luminex Assay for Antigen Detection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Cloud-clone","offers":[{"title":"0.01-10ng\/mL \/ 96T \/ typically less than 0.003 ng\/mL","offer_id":47566587429144,"sku":"LMC586Hu","price":840.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/5652\/1400\/products\/LMC586Hu_b15167a7-56d6-4403-938c-0543e6c0e53d.jpg?v=1705948623","url":"https:\/\/danabiosci.com\/products\/new-product-614017","provider":"Dana Bioscience","version":"1.0","type":"link"}