Cloud-clone
SKU:LMA162Hu
Magnetic Luminex Assay Kit for Olfactomedin 4 (OLFM4) ,etc.
Magnetic Luminex Assay Kit for Olfactomedin 4 (OLFM4) ,etc.
Couldn't load pickup availability
Product No.
LMA162Hu
Organism Species
Homo sapiens (Human).
Sample Type
serum, plasma, tissue homogenates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
1.95-2000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.65 pg/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Olfactomedin 4 (OLFM4) ,etc..
No significant cross-reactivity or interference between Olfactomedin 4 (OLFM4) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Olfactomedin 4 (OLFM4) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Olfactomedin 4 (OLFM4) ,etc. in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 78-101 | 91 |
| EDTA plasma(n=5) | 79-97 | 90 |
| heparin plasma(n=5) | 80-105 | 88 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Olfactomedin 4 (OLFM4) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Olfactomedin 4 (OLFM4) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Olfactomedin 4 (OLFM4) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 85-92% | 85-101% | 78-99% | 81-89% |
| EDTA plasma(n=5) | 91-98% | 85-101% | 80-102% | 78-101% |
| heparin plasma(n=5) | 86-93% | 80-102% | 89-97% | 85-93% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:OLFM4) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
| Magazine | Citations |
| Molecular & Cellular Proteomics | Integrated Proteomic Profiling of Cell Line Conditioned Media and Pancreatic Juice for the Identification of Pancreatic Cancer Biomarkers PubMed: PMC3205865 |
| PLoS One | Olfactomedin 4 serves as a marker for disease severity in pediatric respiratory syncytial virus (RSV) infection PubMed: 26162090 |
| 网页打不开 | Olfactomedin-4 serves as a prognostic marker for disease severity in pediatric respiratory syncytial virus infection 10.1.1.930.8821 |
| DSpace | Maksa rakuvälise maatriksi komponentide muutuste iseloomustamine maksakahjustuse korral handle:10062 |
| ANNALS OF TRANSLATIONAL MEDICINE | Serum levels of olfactomedin 4: a biomarker for asthma control state in asthmatics Pubmed: 32395538 |
| BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS | Notch and TNF-¦Á signaling promote cytoplasmic accumulation of OLFM4 in intestinal epithelium cells and exhibit a cell protective role in the inflamed mucosa?¡ 33490652 |
| J Inflamm Res | OLFM4 Regulates Lung Epithelial Cell Function in Sepsis-Associated ARDS/ALI via LDHA-Mediated NF-κB Signaling 34955649 |
| Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
| RPA162Hu01 | Recombinant Olfactomedin 4 (OLFM4) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAA162Hu01 | Polyclonal Antibody to Olfactomedin 4 (OLFM4) | WB; IHC; ICC; IP. |
| LAA162Hu71 | Biotin-Linked Polyclonal Antibody to Olfactomedin 4 (OLFM4) | WB; IHC; ICC. |
| MAA162Hu22 | Monoclonal Antibody to Olfactomedin 4 (OLFM4) | WB; IHC; ICC; IP. |
| SEA162Hu | ELISA Kit for Olfactomedin 4 (OLFM4) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMA162Hu | Magnetic Luminex Assay Kit for Olfactomedin 4 (OLFM4) ,etc. | Magnetic Luminex Assay for Antigen Detection. |