{"product_id":"new-product-613437","title":"Magnetic Luminex Assay Kit for Synuclein Alpha (SNCa) ,etc.","description":"\u003cp data-mce-fragment=\"1\"\u003eProduct No.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eLMB222Ra\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eOrganism Species\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eRattus norvegicus (Rat).\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSample Type\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eTest Method\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eDouble-antibody Sandwich\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAssay Length\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3.5h\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eDetection Range\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.98-1000pg\/mL\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSensitivity\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe minimum detectable dose of this kit is typically less than 0.327 pg\/mL.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eUOM\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cdiv class=\"product\"\u003e\n\u003cdiv class=\"product_left\"\u003e\n\u003ch3\u003eSpecificity\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThis assay has high sensitivity and excellent specificity for detection of Synuclein Alpha (SNCa) ,etc..\u003cbr\u003eNo significant cross-reactivity or interference between Synuclein Alpha (SNCa) ,etc. and analogues was observed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eRecovery\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eMatrices listed below were spiked with certain level of recombinant Synuclein Alpha (SNCa) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Synuclein Alpha (SNCa) ,etc. in samples.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatrix\u003c\/td\u003e\n\u003ctd\u003eRecovery range (%)\u003c\/td\u003e\n\u003ctd\u003eAverage(%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eserum(n=5)\u003c\/td\u003e\n\u003ctd\u003e88-101\u003c\/td\u003e\n\u003ctd\u003e94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEDTA plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e79-102\u003c\/td\u003e\n\u003ctd\u003e87\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eheparin plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e93-104\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003ePrecision\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eIntra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Synuclein Alpha (SNCa) ,etc. were tested 20 times on one plate, respectively.\u003cbr\u003eInter-assay Precision (Precision between assays): 3 samples with low, middle and high level Synuclein Alpha (SNCa) ,etc. were tested on 3 different plates, 8 replicates in each plate.\u003cbr\u003eCV(%) = SD\/meanX100\u003cbr\u003eIntra-Assay: CV\u0026lt;10%\u003cbr\u003eInter-Assay: CV\u0026lt;12%\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinearity\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe linearity of the kit was assayed by testing samples spiked with appropriate concentration of Synuclein Alpha (SNCa) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample\u003c\/td\u003e\n\u003ctd\u003e1:2\u003c\/td\u003e\n\u003ctd\u003e1:4\u003c\/td\u003e\n\u003ctd\u003e1:8\u003c\/td\u003e\n\u003ctd\u003e1:16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eserum(n=5)\u003c\/td\u003e\n\u003ctd\u003e87-103%\u003c\/td\u003e\n\u003ctd\u003e97-105%\u003c\/td\u003e\n\u003ctd\u003e80-98%\u003c\/td\u003e\n\u003ctd\u003e83-93%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEDTA plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e83-102%\u003c\/td\u003e\n\u003ctd\u003e85-95%\u003c\/td\u003e\n\u003ctd\u003e92-105%\u003c\/td\u003e\n\u003ctd\u003e82-101%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eheparin plasma(n=5)\u003c\/td\u003e\n\u003ctd\u003e89-97%\u003c\/td\u003e\n\u003ctd\u003e87-101%\u003c\/td\u003e\n\u003ctd\u003e78-96%\u003c\/td\u003e\n\u003ctd\u003e90-97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eStability\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.\u003cbr\u003eTo minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eReagents and materials provided\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"reagent_div\"\u003e\n\u003ctable class=\"reagent_table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first_tr\"\u003e\n\u003ctd\u003eReagents\u003c\/td\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003eReagents\u003c\/td\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e96-well plate\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003ePlate sealer for 96 wells\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-Mixed Standard\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1×20mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-Mixed Magnetic beads (22#:SNCa)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eAnalysis buffer\u003c\/td\u003e\n\u003ctd\u003e1×20mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-Mixed Detection Reagent A\u003c\/td\u003e\n\u003ctd\u003e1×120μL\u003c\/td\u003e\n\u003ctd\u003eAssay Diluent A\u003c\/td\u003e\n\u003ctd\u003e1×12mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Reagent B (PE-SA)\u003c\/td\u003e\n\u003ctd\u003e1×120μL\u003c\/td\u003e\n\u003ctd\u003eAssay Diluent B\u003c\/td\u003e\n\u003ctd\u003e1×12mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath Fluid\u003c\/td\u003e\n\u003ctd\u003e1×10mL\u003c\/td\u003e\n\u003ctd\u003eWash Buffer (30 × concentrate)\u003c\/td\u003e\n\u003ctd\u003e1×20mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstruction manual\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAssay procedure summary\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003e1. Preparation of standards, reagents and samples before the experiment;\u003cbr\u003e2. Add 100μL standard or sample to each well,\u003cbr\u003e    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;\u003cbr\u003e3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;\u003cbr\u003e4. Wash plate on magnetic frame for three times;\u003cbr\u003e5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;\u003cbr\u003e6. Wash plate on magnetic frame for three times;\u003cbr\u003e7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_reference\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first_tr\"\u003e\n\u003ctd class=\"td_1\"\u003eMagazine\u003c\/td\u003e\n\u003ctd\u003eCitations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe Journal of Clinical Investigation\u003c\/td\u003e\n\u003ctd\u003eCerebrospinal fluid–based kinetic biomarkers of axonal transport in monitoring neurodegeneration\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"http:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC3428100\/\" target=\"_blank\"\u003ePubMed: PMC3428100\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeurobiology of Disease\u003c\/td\u003e\n\u003ctd\u003eLysosomal dysfunction increases exosome-mediated alpha-synuclein release and transmission\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"http:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC3107939\/\" target=\"_blank\"\u003ePubMed: PMC3107939\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNature Communications\u003c\/td\u003e\n\u003ctd\u003eParkinson's disease induced pluripotent stem cells with triplication of the α-synuclein locus\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"http:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC3265381\/\" target=\"_blank\"\u003ePubMed: PMC3265381\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProvisional chapter\u003c\/td\u003e\n\u003ctd\u003eMutations of PARK Genes and Alpha-Synuclein and Parkin Concentrations in Parkinson’s Disease\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"http:\/\/cdn.intechopen.com\/pdfs-wm\/46430.pdf\" target=\"_blank\"\u003eIntechopen:Source\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNerodegeneration\u003c\/td\u003e\n\u003ctd\u003eApolipoprotein Eε4: A Biomarker for Executive Dysfunction among Parkinson's Disease Patients with Mild Cognitive Impairment\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/29326545\" target=\"_blank\"\u003epubmed:29326545\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExperimental gerontology\u003c\/td\u003e\n\u003ctd\u003eThe anti-aging protein klotho alleviates injury of nigrostriatal dopaminergic pathway in 6-hydroxydopamine rat model of Parkinson's disease: Involvement of PKA\/CaMKII\/CREB signaling.\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/29107062\" target=\"_blank\"\u003epubmed:29107062\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeurobiology of Disease\u003c\/td\u003e\n\u003ctd\u003eDevelopment and biochemical characterization of a mouse model of Parkinson's disease bearing defective glucocerebrosidase activity\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/www.sciencedirect.com\/science\/article\/pii\/S0969996118307563\" target=\"_blank\"\u003ePubmed: 30521842\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emolecular and cellular biochemistry\u003c\/td\u003e\n\u003ctd\u003ePotential therapeutic effects of antagonizing adenosine A2A receptor, curcumin and niacin in rotenone-induced Parkinson's disease mice model\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/31820278\/\" target=\"_blank\"\u003ePubmed: 31820278\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternational Journal of Pharmacology\u003c\/td\u003e\n\u003ctd\u003eNose to brain delivery of rotigotine loaded chitosan nanoparticles in human SH-SY5Y neuroblastoma cells and animal model of Parkinson's disease\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/32084576\/\" target=\"_blank\"\u003ePubmed: 32084576\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEBioMedicine\u003c\/td\u003e\n\u003ctd\u003eAnti-α-synuclein ASO delivered to monoamine neurons prevents α-synuclein accumulation in a Parkinson's disease-like mouse model and in monkeys\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/32810825\/\" target=\"_blank\"\u003ePubmed: 32810825\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_relation\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first_tr\"\u003e\n\u003ctd class=\"td_1\"\u003eCatalog No.\u003c\/td\u003e\n\u003ctd class=\"td_2\"\u003eRelated products for research use of Rattus norvegicus (Rat) Organism species\u003c\/td\u003e\n\u003ctd class=\"td_3\"\u003eApplications (RESEARCH USE ONLY!)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRPB222Ra01\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/RPB222Ra01.html\"\u003eRecombinant Synuclein Alpha (SNCa)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive Control; Immunogen; SDS-PAGE; WB.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAB222Ra01\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/PAB222Ra01.html\"\u003ePolyclonal Antibody to Synuclein Alpha (SNCa)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWB; IHC; ICC; IP.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAB222Ra21\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/MAB222Ra21.html\"\u003eMonoclonal Antibody to Synuclein Alpha (SNCa)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWB; IHC; ICC; IP.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEB222Ra\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/SEB222Ra.html\"\u003eELISA Kit for Synuclein Alpha (SNCa)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eEnzyme-linked immunosorbent assay for Antigen Detection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLMB222Ra\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/LMB222Ra.html\"\u003eMagnetic Luminex Assay Kit for Synuclein Alpha (SNCa) ,etc.\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnetic Luminex Assay for Antigen Detection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKSB222Ra01\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/KSB222Ra01.html\"\u003eELISA Kit DIY Materials for Synuclein Alpha (SNCa)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMain materials for \"Do It (ELISA Kit) Yourself\".\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"more_info\"\u003e\u003c\/div\u003e","brand":"Cloud-clone","offers":[{"title":"0.98-1000pg\/mL \/ 96T \/ typically less than 0.327 pg\/mL","offer_id":47566229569816,"sku":"LMB222Ra","price":866.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/5652\/1400\/products\/LMB222Ra_56524cbb-6db3-4717-8ef0-c2487afe7488.jpg?v=1705945270","url":"https:\/\/danabiosci.com\/products\/new-product-613437","provider":"Dana Bioscience","version":"1.0","type":"link"}