{"product_id":"new-product-610299","title":"Magnetic Luminex Assay Kit for Phosphoinositide-3-Kinase Catalytic Delta Polypeptide (PIK3Cd) ,etc.","description":"\u003cdiv class=\"product_left\" data-mce-fragment=\"1\"\u003e\n\u003cp\u003eProduct No.\u003c\/p\u003e\n\u003cp\u003eLMJ832Hu\u003c\/p\u003e\n\u003cp\u003eOrganism Species\u003c\/p\u003e\n\u003cp\u003eHomo sapiens (Human).\u003c\/p\u003e\n\u003cp\u003eSample Type\u003c\/p\u003e\n\u003cp\u003eTissue homogenates, cell lysates and other biological fluids\u003c\/p\u003e\n\u003cp\u003eTest Method\u003c\/p\u003e\n\u003cp\u003eDouble-antibody Sandwich\u003c\/p\u003e\n\u003cp\u003eAssay Length\u003c\/p\u003e\n\u003cp\u003e3.5h\u003c\/p\u003e\n\u003cp\u003eDetection Range\u003c\/p\u003e\n\u003cp\u003e0.02-20ng\/mL\u003c\/p\u003e\n\u003cp\u003eSensitivity\u003c\/p\u003e\n\u003cp\u003eThe minimum detectable dose of this kit is typically less than 0.007 ng\/mL.\u003c\/p\u003e\n\u003cp\u003eUOM\u003c\/p\u003e\n\u003cp\u003e1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eSpecificity\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis assay has high sensitivity and excellent specificity for detection of Phosphoinositide-3-Kinase Catalytic Delta Polypeptide (PIK3Cd) ,etc..\u003cbr data-mce-fragment=\"1\"\u003eNo significant cross-reactivity or interference between Phosphoinositide-3-Kinase Catalytic Delta Polypeptide (PIK3Cd) ,etc. and analogues was observed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eRecovery\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eMatrices listed below were spiked with certain level of recombinant Phosphoinositide-3-Kinase Catalytic Delta Polypeptide (PIK3Cd) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Phosphoinositide-3-Kinase Catalytic Delta Polypeptide (PIK3Cd) ,etc. in samples.\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMatrix\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRecovery range (%)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAverage(%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eserum(n=5)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e96-104\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEDTA plasma(n=5)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e83-90\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eheparin plasma(n=5)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e92-101\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003esodium citrate plasma(n=5)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e95-103\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003ePrecision\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIntra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Phosphoinositide-3-Kinase Catalytic Delta Polypeptide (PIK3Cd) ,etc. were tested 20 times on one plate, respectively.\u003cbr data-mce-fragment=\"1\"\u003eInter-assay Precision (Precision between assays): 3 samples with low, middle and high level Phosphoinositide-3-Kinase Catalytic Delta Polypeptide (PIK3Cd) ,etc. were tested on 3 different plates, 8 replicates in each plate.\u003cbr data-mce-fragment=\"1\"\u003eCV(%) = SD\/meanX100\u003cbr data-mce-fragment=\"1\"\u003eIntra-Assay: CV\u0026lt;10%\u003cbr data-mce-fragment=\"1\"\u003eInter-Assay: CV\u0026lt;12%\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eLinearity\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe linearity of the kit was assayed by testing samples spiked with appropriate concentration of Phosphoinositide-3-Kinase Catalytic Delta Polypeptide (PIK3Cd) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSample\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1:2\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1:4\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1:8\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1:16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eserum(n=5)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e80-94%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e95-103%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e85-103%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e80-103%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEDTA plasma(n=5)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e87-95%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e80-90%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e94-104%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e80-96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eheparin plasma(n=5)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e80-101%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e83-102%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e81-92%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e96-103%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003esodium citrate plasma(n=5)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e87-101%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e86-93%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e94-103%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e92-105%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eStability\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.\u003cbr data-mce-fragment=\"1\"\u003eTo minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eReagents and materials provided\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"reagent_div\" data-mce-fragment=\"1\"\u003e\n\u003ctable class=\"reagent_table\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr class=\"first_tr\" data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eReagents\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eQuantity\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eReagents\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eQuantity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e96-well plate\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePlate sealer for 96 wells\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePre-Mixed Standard\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e2\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×20mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePre-Mixed Magnetic beads (22#:PIK3Cd)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAnalysis buffer\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×20mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePre-Mixed Detection Reagent A\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×120μL\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAssay Diluent A\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×12mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eDetection Reagent B (PE-SA)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×120μL\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAssay Diluent B\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×12mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSheath Fluid\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×10mL\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWash Buffer (30 × concentrate)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×20mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eInstruction manual\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eAssay procedure summary\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1. Preparation of standards, reagents and samples before the experiment;\u003cbr data-mce-fragment=\"1\"\u003e2. Add 100μL standard or sample to each well,\u003cbr data-mce-fragment=\"1\"\u003e    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;\u003cbr data-mce-fragment=\"1\"\u003e3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;\u003cbr data-mce-fragment=\"1\"\u003e4. Wash plate on magnetic frame for three times;\u003cbr data-mce-fragment=\"1\"\u003e5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;\u003cbr data-mce-fragment=\"1\"\u003e6. Wash plate on magnetic frame for three times;\u003cbr data-mce-fragment=\"1\"\u003e7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_relation\" data-mce-fragment=\"1\"\u003e\n\u003ctable data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr class=\"first_tr\" data-mce-fragment=\"1\"\u003e\n\u003ctd class=\"td_1\" data-mce-fragment=\"1\"\u003eCatalog No.\u003c\/td\u003e\n\u003ctd class=\"td_2\" data-mce-fragment=\"1\"\u003eRelated products for research use of Homo sapiens (Human) Organism species\u003c\/td\u003e\n\u003ctd class=\"td_3\" data-mce-fragment=\"1\"\u003eApplications (RESEARCH USE ONLY!)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRPJ832Hu01\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/RPJ832Hu01.html\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.cloud-clone.com\/products\/RPJ832Hu01.html\"\u003eRecombinant Phosphoinositide-3-Kinase Catalytic Delta Polypeptide (PIK3Cd)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePositive Control; Immunogen; SDS-PAGE; WB.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePAJ832Hu01\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/PAJ832Hu01.html\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.cloud-clone.com\/products\/PAJ832Hu01.html\"\u003ePolyclonal Antibody to Phosphoinositide-3-Kinase Catalytic Delta Polypeptide (PIK3Cd)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWB; ICC; IHC-P; IHC-F; ELISA.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMAJ832Hu21\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/MAJ832Hu21.html\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.cloud-clone.com\/products\/MAJ832Hu21.html\"\u003eMonoclonal Antibody to Phosphoinositide-3-Kinase Catalytic Delta Polypeptide (PIK3Cd)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWB; IHC; ICC; IP.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSEJ832Hu\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/SEJ832Hu.html\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.cloud-clone.com\/products\/SEJ832Hu.html\"\u003eELISA Kit for Phosphoinositide-3-Kinase Catalytic Delta Polypeptide (PIK3Cd)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEnzyme-linked immunosorbent assay for Antigen Detection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eLMJ832Hu\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/LMJ832Hu.html\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.cloud-clone.com\/products\/LMJ832Hu.html\"\u003eMagnetic Luminex Assay Kit for Phosphoinositide-3-Kinase Catalytic Delta Polypeptide (PIK3Cd) ,etc.\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMagnetic Luminex Assay for Antigen Detection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Cloud-clone","offers":[{"title":"0.02-20ng\/mL \/ 96T \/ typically less than 0.007 ng\/mL","offer_id":47562800890136,"sku":"LMJ832Hu","price":840.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/5652\/1400\/products\/LMJ832Hu_5b2b666a-23ca-4c78-90c9-8ee9522f6986.jpg?v=1705904886","url":"https:\/\/danabiosci.com\/products\/new-product-610299","provider":"Dana Bioscience","version":"1.0","type":"link"}