{"product_id":"new-product-610010","title":"Magnetic Luminex Assay Kit for Colony Stimulating Factor 3, Granulocyte (GCSF) ,etc.","description":"\u003cdiv class=\"product_import\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eProduct No.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eLMA042Hu\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eOrganism Species\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eHomo sapiens (Human).\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSample Type\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eTest Method\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eDouble-antibody Sandwich\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAssay Length\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3.5h\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eDetection Range\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.98-1000pg\/mL\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSensitivity\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe minimum detectable dose of this kit is typically less than 0.327 pg\/mL.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eUOM\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eSpecificity\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis assay has high sensitivity and excellent specificity for detection of Colony Stimulating Factor 3, Granulocyte (GCSF) ,etc..\u003cbr data-mce-fragment=\"1\"\u003eNo significant cross-reactivity or interference between Colony Stimulating Factor 3, Granulocyte (GCSF) ,etc. and analogues was observed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eRecovery\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eMatrices listed below were spiked with certain level of recombinant Colony Stimulating Factor 3, Granulocyte (GCSF) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Colony Stimulating Factor 3, Granulocyte (GCSF) ,etc. in samples.\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMatrix\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRecovery range (%)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAverage(%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eserum(n=5)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e90-98\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEDTA plasma(n=5)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e84-98\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eheparin plasma(n=5)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e78-90\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003ePrecision\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIntra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Colony Stimulating Factor 3, Granulocyte (GCSF) ,etc. were tested 20 times on one plate, respectively.\u003cbr data-mce-fragment=\"1\"\u003eInter-assay Precision (Precision between assays): 3 samples with low, middle and high level Colony Stimulating Factor 3, Granulocyte (GCSF) ,etc. were tested on 3 different plates, 8 replicates in each plate.\u003cbr data-mce-fragment=\"1\"\u003eCV(%) = SD\/meanX100\u003cbr data-mce-fragment=\"1\"\u003eIntra-Assay: CV\u0026lt;10%\u003cbr data-mce-fragment=\"1\"\u003eInter-Assay: CV\u0026lt;12%\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eLinearity\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe linearity of the kit was assayed by testing samples spiked with appropriate concentration of Colony Stimulating Factor 3, Granulocyte (GCSF) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSample\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1:2\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1:4\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1:8\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1:16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eserum(n=5)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e97-105%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e80-98%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e82-95%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e80-99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEDTA plasma(n=5)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e97-104%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e81-102%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e88-102%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e97-105%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eheparin plasma(n=5)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e93-101%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e80-96%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e80-90%\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e83-97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eStability\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.\u003cbr data-mce-fragment=\"1\"\u003eTo minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eReagents and materials provided\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"reagent_div\" data-mce-fragment=\"1\"\u003e\n\u003ctable class=\"reagent_table\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr class=\"first_tr\" data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eReagents\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eQuantity\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eReagents\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eQuantity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e96-well plate\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePlate sealer for 96 wells\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePre-Mixed Standard\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e2\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×20mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePre-Mixed Magnetic beads (22#:GCSF)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAnalysis buffer\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×20mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePre-Mixed Detection Reagent A\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×120μL\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAssay Diluent A\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×12mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eDetection Reagent B (PE-SA)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×120μL\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAssay Diluent B\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×12mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSheath Fluid\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×10mL\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWash Buffer (30 × concentrate)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1×20mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eInstruction manual\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eAssay procedure summary\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1. Preparation of standards, reagents and samples before the experiment;\u003cbr data-mce-fragment=\"1\"\u003e2. Add 100μL standard or sample to each well,\u003cbr data-mce-fragment=\"1\"\u003e    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;\u003cbr data-mce-fragment=\"1\"\u003e3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;\u003cbr data-mce-fragment=\"1\"\u003e4. Wash plate on magnetic frame for three times;\u003cbr data-mce-fragment=\"1\"\u003e5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;\u003cbr data-mce-fragment=\"1\"\u003e6. Wash plate on magnetic frame for three times;\u003cbr data-mce-fragment=\"1\"\u003e7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"product_reference\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first_tr\"\u003e\n\u003ctd class=\"td_1\"\u003eMagazine\u003c\/td\u003e\n\u003ctd\u003eCitations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScientific Reports\u003c\/td\u003e\n\u003ctd\u003eThe Transcriptional Foundations of Sp110-mediated Macrophage (RAW264. 7) Resistance to Mycobacterium tuberculosis H37Ra\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/26912204\" target=\"_blank\"\u003ePubmed:26912204\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternational Journal of Clinical and Experimental Pathology\u003c\/td\u003e\n\u003ctd\u003eLow-density neutrophils in severe fever with thrombocytopenia syndrome (SFTS) display decreased function to phagocytose SFTS virus and enhanced capacity to synthesize cytokines\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"http:\/\/www.ijcep.com\/files\/ijcep0045334.pdf\" target=\"_blank\"\u003eISSN:1936-2625\/IJCEP0045334\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternational Immunopharmacology\u003c\/td\u003e\n\u003ctd\u003eGinsenoside Rg3 improves cyclophosphamide-induced immunocompetence in Balb\/c mice\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/www.sciencedirect.com\/science\/article\/pii\/S1567576918313377\" target=\"_blank\"\u003ePubmed: 30974284\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMol Immunol\u003c\/td\u003e\n\u003ctd\u003eOridonin alleviates kanamycin-related hearing loss by inhibiting NLRP3\/caspase-1\/gasdermin D-induced inflammasome activation and hair cell pyroptosis\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/35749835\/\" target=\"_blank\"\u003ePubmed:35749835\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_relation\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first_tr\"\u003e\n\u003ctd class=\"td_1\"\u003eCatalog No.\u003c\/td\u003e\n\u003ctd class=\"td_2\"\u003eRelated products for research use of Homo sapiens (Human) Organism species\u003c\/td\u003e\n\u003ctd class=\"td_3\"\u003eApplications (RESEARCH USE ONLY!)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPA042Hu01\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/APA042Hu01.html\"\u003eActive Colony Stimulating Factor 3, Granulocyte (GCSF)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCell culture; Activity Assays.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRPA042Hu02\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/RPA042Hu02.html\"\u003eRecombinant Colony Stimulating Factor 3, Granulocyte (GCSF)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive Control; Immunogen; SDS-PAGE; WB.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRPA042Hu01\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/RPA042Hu01.html\"\u003eRecombinant Colony Stimulating Factor 3, Granulocyte (GCSF)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive Control; Immunogen; SDS-PAGE; WB.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAA042Hu01\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/PAA042Hu01.html\"\u003ePolyclonal Antibody to Colony Stimulating Factor 3, Granulocyte (GCSF)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAA042Hu02\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/PAA042Hu02.html\"\u003ePolyclonal Antibody to Colony Stimulating Factor 3, Granulocyte (GCSF)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWB; IHC; ICC; IP.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAA042Hu22\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/MAA042Hu22.html\"\u003eMonoclonal Antibody to Colony Stimulating Factor 3, Granulocyte (GCSF)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWB; IHC; ICC; IP.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEA042Hu\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/SEA042Hu.html\"\u003eELISA Kit for Colony Stimulating Factor 3, Granulocyte (GCSF)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eEnzyme-linked immunosorbent assay for Antigen Detection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMEA042Hu\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/MEA042Hu.html\"\u003eMini Samples ELISA Kit for Colony Stimulating Factor 3, Granulocyte (GCSF)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eEnzyme-linked immunosorbent assay for Antigen Detection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCA042Hu\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/SCA042Hu.html\"\u003eCLIA Kit for Colony Stimulating Factor 3, Granulocyte (GCSF)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eChemiluminescent immunoassay for Antigen Detection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLMA042Hu\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/LMA042Hu.html\"\u003eMagnetic Luminex Assay Kit for Colony Stimulating Factor 3, Granulocyte (GCSF) ,etc.\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnetic Luminex Assay for Antigen Detection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePGA042Hu02\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.cloud-clone.com\/products\/PGA042Hu02.html\"\u003ePrimer Pair for Colony Stimulating Factor 3, Granulocyte (GCSF)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ePCR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cloud-clone","offers":[{"title":"0.98-1000pg\/mL \/ 96T \/ typically less than 0.327 pg\/mL","offer_id":47562700390680,"sku":"LMA042Hu","price":670.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/5652\/1400\/products\/LMA042Hu_a850417b-075a-4215-aed3-5112497b5fe4.jpg?v=1705903720","url":"https:\/\/danabiosci.com\/products\/new-product-610010","provider":"Dana Bioscience","version":"1.0","type":"link"}