{"product_id":"new-product-590540","title":"Human DMD(Dystrophin) ELISA Kit","description":"\u003cp\u003eThe Human DMD(Dystrophin) ELISA Kit by FineTest is a reliable and accurate tool for quantitative detection of DMD (Dystrophin) in human samples. Designed as an ELISA kit, this product offers a convenient and efficient method for researchers and clinicians to assess DMD levels in various biological samples.\u003c\/p\u003e\n\u003cp\u003eWith a sensitivity of 0.094ng\/ml, this kit allows for the detection of even low levels of DMD. The wide range of 0.156-10ng\/ml ensures that a broad range of DMD concentrations can be measured accurately.\u003c\/p\u003e\n\u003cp\u003eThis kit is available in a 96T size, providing ample capacity for multiple experiments and analyses. The easy-to-use format simplifies the testing process, saving time and effort in the laboratory.\u003c\/p\u003e\n\u003cp\u003eThe Human DMD(Dystrophin) ELISA Kit is suitable for use in research studies and clinical diagnostics related to DMD. Its high sensitivity and specificity make it a valuable tool for understanding the mechanisms underlying DMD pathogenesis and assessing treatment efficacy.\u003c\/p\u003e\n\u003cp\u003eFineTest is a trusted vendor known for its high-quality products, and this ELISA kit is no exception. It is designed to deliver reliable and reproducible results, ensuring the accuracy of your experiments.\u003c\/p\u003e\n\u003cp\u003eWith its convenient packaging and easy-to-follow instructions, the Human DMD(Dystrophin) ELISA Kit is an essential tool for researchers and clinicians working in the field of DMD. Trust FineTest to provide you with the tools you need to advance your research and improve diagnosis in the fight against DMD.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eProduct Name\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eHuman DMD(Dystrophin) ELISA Kit\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAlias\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eDMD ELISA Kit\u003c\/span\u003e\u003c\/i\u003e\u003cspan style=\"font-weight: 400;\"\u003e, \u003c\/span\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eDystrophin ELISA Kit\u003c\/span\u003e\u003c\/i\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDetection Method\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSandwich ELISA, Double Antibody\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.fn-test.com\/?post_type=product\u0026amp;s=DMD\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eDMD ELISA Kit\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"font-weight: 400;\"\u003e allows for the in vitro quantitative determination of DMD concentrations in serum, plasma, tissue homogenates and other biological fluids.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSize\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e96T\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e0.156-10ng\/ml\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSensitivity\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u0026lt; 0.094ng\/ml\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSpecies\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eHuman\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eUniProt ID\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/www.uniprot.org\/uniprot\/P11532\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eP11532\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eStandard Curve\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cimg src=\"https:\/\/www.fn-test.com\/content\/uploads\/product\/images\/elisa\/standard-curve\/EH1726.jpg\"\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eStorage\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e2-8 ℃ for 6 months\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eRecovery\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMatrices listed below were spiked with certain level of DMD and the recovery rates were calculated by comparing the measured value to the expected amount of DMD in samples.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eMatrix\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eRecovery range(%)\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eAverage(%)\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eserum(n=5)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e98-103\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e100\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eEDTA plasma(n=5)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e86-103\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e92\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eheparin plasma(n=5)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e87-105\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e95\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eLinearity\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe linearity of the kit was assayed by testing samples spiked with appropriate concentration of DMD and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eSample\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003e1:2\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003e1:4\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003e1:8\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eserum(n=5)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e85-104%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e91-100%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e88-101%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eEDTA plasma(n=5)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e90-99%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e86-100%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e90-100%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eheparin plasma(n=5)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e89-100%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e83-100%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e95-99%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eCV(%)\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eIntra-Assay: CV\u0026lt;8%\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eInter-Assay: CV\u0026lt;10%\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNote\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFor Research Use Only\u003c\/span\u003e\u003c\/p\u003e","brand":"FineTest","offers":[{"title":"96T \/ 0.094ng\/ml \/ 0.156-10ng\/ml","offer_id":47556993745176,"sku":"EH1726","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/5652\/1400\/products\/EM2109_c2b3ce14-4bda-4da4-ba61-aca7f5dcca7d.jpg?v=1705776883","url":"https:\/\/danabiosci.com\/products\/new-product-590540","provider":"Dana Bioscience","version":"1.0","type":"link"}