{"product_id":"new-product-590532","title":"Human TTPAL(Alpha-tocopherol transfer protein-like) ELISA Kit","description":"\u003cp\u003eThe human TTPAL (Alpha-tocopherol transfer protein-like) ELISA Kit is a high-quality product offered by FineTest. This ELISA kit is specifically designed for research purposes and is suitable for detecting the TTPAL protein in a human sample.\u003c\/p\u003e\n\u003cp\u003eWith a sensitivity of 0.938ng\/ml, this kit ensures accurate and reliable results. The wide range of detection, from 1.563-100ng\/ml, allows for the analysis of a broad spectrum of protein concentrations.\u003c\/p\u003e\n\u003cp\u003eThe kit comes in a convenient size of 96T, providing enough reagents for multiple experiments. The alpha-tocopherol transfer protein-like ELISA kit is supplied with everything needed, including assay plates, buffers, and a detailed instruction manual, making it user-friendly and easy to use.\u003c\/p\u003e\n\u003cp\u003eThis ELISA kit is designed to be used manually and requires no additional inventory tracking. It has been priced at $450, offering great value for researchers and laboratories. Additionally, it is available for shipping both within the United States and internationally.\u003c\/p\u003e\n\u003cp\u003eThe product image showcases the kit's components, providing a visual representation of what is included. It is worth mentioning that this kit is only intended for research purposes and should not be used for diagnostic or therapeutic applications.\u003c\/p\u003e\n\u003cp\u003eOverall, the human TTPAL (Alpha-tocopherol transfer protein-like) ELISA Kit presented by FineTest is a reliable and efficient tool for researchers working in the field. With its high sensitivity and broad detection range, it enables accurate and precise measurement of TTPAL protein levels in human samples.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eProduct Name\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eHuman TTPAL(Alpha-tocopherol transfer protein-like) ELISA Kit\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAlias\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eTTPAL ELISA Kit\u003c\/span\u003e\u003c\/i\u003e\u003cspan style=\"font-weight: 400;\"\u003e, \u003c\/span\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eAlpha-tocopherol transfer protein-like ELISA Kit\u003c\/span\u003e\u003c\/i\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDetection Method\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eCompetitive ELISA, Coated with Antigen\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.fn-test.com\/?post_type=product\u0026amp;s=TTPAL\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eTTPAL ELISA Kit\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"font-weight: 400;\"\u003e allows for the in vitro quantitative determination of TTPAL concentrations in serum, plasma, tissue homogenates and other biological fluids.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSize\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e96T\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e1.56-100ng\/ml\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSensitivity\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u0026lt; 0.938ng\/ml\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSpecies\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eHuman\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eUniProt ID\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/www.uniprot.org\/uniprot\/Q9BTX7\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eQ9BTX7\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eStandard Curve\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cimg src=\"https:\/\/www.fn-test.com\/content\/uploads\/product\/images\/elisa\/standard-curve\/EH1712.jpg\"\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eStorage\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e2-8 ℃ for 6 months\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eRecovery\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMatrices listed below were spiked with certain level of TTPAL and the recovery rates were calculated by comparing the measured value to the expected amount of TTPAL in samples.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eMatrix\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eRecovery range(%)\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eAverage(%)\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eserum(n=5)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e92-102\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e97\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eEDTA plasma(n=5)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e86-103\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e94\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eheparin plasma(n=5)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e90-104\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e95\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eLinearity\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe linearity of the kit was assayed by testing samples spiked with appropriate concentration of TTPAL and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eSample\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003e1:2\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003e1:4\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003e1:8\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eserum(n=5)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e88-97%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e89-104%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e88-103%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eEDTA plasma(n=5)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e90-97%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e83-100%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e84-97%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eheparin plasma(n=5)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e81-100%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e80-100%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e80-97%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eCV(%)\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eIntra-Assay: CV\u0026lt;8%\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eInter-Assay: CV\u0026lt;10%\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNote\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFor Research Use Only\u003c\/span\u003e\u003c\/p\u003e","brand":"FineTest","offers":[{"title":"96T \/ 0.938ng\/ml \/ 1.563-100ng\/ml","offer_id":47556990533912,"sku":"EH1712","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/5652\/1400\/products\/EM2109_e1dab1e5-01b5-4697-bee8-45f510566f0e.jpg?v=1705776856","url":"https:\/\/danabiosci.com\/products\/new-product-590532","provider":"Dana Bioscience","version":"1.0","type":"link"}